a:6:{s:1:"k";s:46:"categories-v1-c5a5942ef4e178aa6225d77120fc8928";s:1:"d";a:13:{i:0;a:21:{s:14:"products_fsk18";i:0;s:23:"products_date_available";s:19:"0000-00-00 00:00:00";s:21:"products_shippingtime";i:1;s:14:"products_model";s:19:"SUN-2K-G04P1-EU-AM1";s:15:"products_master";i:0;s:22:"products_master_status";i:0;s:12:"products_ean";s:0:"";s:13:"products_name";s:59:"SUN-2K-G04P1-EU-AM1 | Single Phase String Inverter | 1 MPPT";s:19:"products_extra_text";s:8228:"<table style="width: 100%; border-collapse: collapse; background: #fff; border-radius: 14px; overflow: hidden; box-shadow: 0 10px 35px rgba(0,0,0,.12); margin: 60px 0; font-size: 15px;">
<tbody>
<tr style="background: #30358C; color: white;"><th style="padding: 20px; text-align: left; font-weight: 600;">Parameter</th><th style="padding: 20px; text-align: left; font-weight: 600;">Value</th></tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">Single-Phase String Inverter SUN-2K-G04P1-EU-AM1</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">PV String Input Data</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Max. PV Input Power</td>
<td style="padding: 14px 20px;">2.6 kW</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Max. PV Input Voltage</td>
<td style="padding: 14px 20px;">550 V</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Start-up Voltage</td>
<td style="padding: 14px 20px;">80 V</td>
</tr>
<tr>
<td style="padding: 14px 20px;">MPPT Voltage Range</td>
<td style="padding: 14px 20px;">70&#8211;500 V</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated PV Input Voltage</td>
<td style="padding: 14px 20px;">360 V</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Max. Operating PV Input Current</td>
<td style="padding: 14px 20px;">20 A</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Max. Input Short Circuit Current</td>
<td style="padding: 14px 20px;">30 A</td>
</tr>
<tr>
<td style="padding: 14px 20px;">No. of MPP Trackers / Strings per MPP Tracker</td>
<td style="padding: 14px 20px;">1 / 1</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">AC Output Side</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated AC Output Active Power</td>
<td style="padding: 14px 20px;">2 kW</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Max. AC Output Apparent Power</td>
<td style="padding: 14px 20px;">2.2 kVA</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated AC Output Current (230 V / 220 V)</td>
<td style="padding: 14px 20px;">8.7 A / 9.1 A</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Max. AC Output Current (230 V / 220 V)</td>
<td style="padding: 14px 20px;">9.6 A / 10 A</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated Output Voltage / Range</td>
<td style="padding: 14px 20px;">220/230 V (0.85 Un &#8211; 1.1 Un)</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Grid Connection Form</td>
<td style="padding: 14px 20px;">L+N+PE</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated Grid Frequency / Range</td>
<td style="padding: 14px 20px;">50/60 Hz (45&#8211;55 / 55&#8211;65 Hz)</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Power Factor Adjustment Range</td>
<td style="padding: 14px 20px;">0.8 leading &#8211; 0.8 lagging</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Total Harmonic Distortion (THDi)</td>
<td style="padding: 14px 20px;">&lt; 3 %</td>
</tr>
<tr>
<td style="padding: 14px 20px;">DC Injection Current</td>
<td style="padding: 14px 20px;">&lt; 0.5 % In</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">Efficiency</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Max. Efficiency</td>
<td style="padding: 14px 20px;">97.3 %</td>
</tr>
<tr>
<td style="padding: 14px 20px;">European Efficiency</td>
<td style="padding: 14px 20px;">96.9 %</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">MPPT Efficiency</td>
<td style="padding: 14px 20px;">&gt; 99 %</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">Equipment Protection</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">DC Polarity Reverse Connection Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">AC Output Overcurrent Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">AC Output Overvoltage Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">AC Output Short Circuit Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Thermal Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Insulation Impedance Monitoring</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">DC Component Monitoring</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Arc Fault Circuit Interrupter (AFCI)</td>
<td style="padding: 14px 20px;">Optional</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Anti-Islanding Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Residual Current Detection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Surge Protection Level</td>
<td style="padding: 14px 20px;">Type II (DC), Type II (AC)</td>
</tr>
<tr>
<td style="padding: 14px 20px;">DC Switch</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">Interface</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Communication Interface</td>
<td style="padding: 14px 20px;">RS485 / RS232</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Monitoring Mode</td>
<td style="padding: 14px 20px;">GPRS / Wi-Fi / Bluetooth / 4G / LAN (optional)</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">General Data</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Operating Temperature Range</td>
<td style="padding: 14px 20px;">-25 &#176;C to +65 &#176;C (&gt;45 &#176;C derating)</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Permissible Ambient Humidity</td>
<td style="padding: 14px 20px;">0&#8211;100 %</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Permissible Altitude</td>
<td style="padding: 14px 20px;">2000 m</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Noise Emission</td>
<td style="padding: 14px 20px;">&#8804; 35 dB</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Ingress Protection Rating</td>
<td style="padding: 14px 20px;">IP65</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Cabinet Size (W &#215; H &#215; D)</td>
<td style="padding: 14px 20px;">280 &#215; 310 &#215; 184 mm (excl. connectors and brackets)</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Weight</td>
<td style="padding: 14px 20px;">6.35 kg</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Type of Cooling</td>
<td style="padding: 14px 20px;">Natural Cooling</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Warranty</td>
<td style="padding: 14px 20px;">5 years</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Grid Regulation</td>
<td style="padding: 14px 20px;">IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, G98, G99, VDE-AR-N 4105</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Safety EMC / Standard</td>
<td style="padding: 14px 20px;">IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1/2</td>
</tr>
</tbody>
</table>";s:17:"products_quantity";i:9999;s:16:"manufacturers_id";i:10;s:14:"products_image";s:10:"1027_0.jpg";s:15:"products_weight";s:6:"8.4000";s:26:"products_short_description";s:403:"Deye SUN-2K-G04P1-EU-AM1 2kW Single-Phase String Inverter (EU)<br /><br />Ultra-light 2 kW single-phase inverter with 97.3 % efficiency, extremely early start at 80 V, zero-export &amp; VSG function, only 6.35 kg, virtually silent (&#8804; 35 dB), IP65, Type II SPD on both sides, fully certified (G99, VDE-AR-N 4105 etc.). Ideal for very small residential systems, extensions, and balcony power plants.";s:20:"products_description";s:3757:"<div style="font-family: 'Segoe UI',Arial,sans-serif; max-width: 1000px; margin: 0 auto; line-height: 1.7; color: #333;">
<p style="font-size: 19px; font-weight: 300; color: #222; margin-bottom: 45px;">The Deye SUN-2K-G04P1-EU-AM1 is a compact, state-of-the-art 2 kW single-phase string inverter &#8211; perfect for very small residential systems, extensions, or balcony power plants. With a peak efficiency of 97.3 % and a European efficiency of 96.9 %, it delivers excellent performance in its class. Thanks to an extremely low start-up voltage of only 80 V, it produces power even in low-light conditions. Zero-export capability, VSG grid support, optional string-level monitoring and optional anti-PID function make it highly flexible and future-proof. Weighing just 6.35 kg, with ultra-compact dimensions of 280 &#215; 310 &#215; 184 mm, natural cooling (barely audible &#8804; 35 dB) and IP65 protection, it can be installed by one person &#8211; indoors or outdoors. Extensive communication options and full certification to all major European standards complete this outstanding package.</p>
<div style="margin: 60px 0;"><img src="https://syd-green-energy.com/files/images/syd-solar-mood-007.jpg" alt="Deye SUN-2K-G04P1-EU-AM1 2kW Single-Phase Inverter" style="width: 100%; border-radius: 14px; box-shadow: 0 12px 35px rgba(0,0,0,.15);" /></div>
<h3 style="color: #30358c; font-size: 30px; font-weight: bold; margin: 70px 0 40px; text-transform: uppercase; letter-spacing: 1.5px;">Key Advantages</h3>
<div style="display: grid; grid-template-columns: repeat(auto-fit,minmax(380px,1fr)); gap: 28px; margin-bottom: 70px;">
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Excellent Efficiency</strong><br />97.3 % peak &#183; 96.9 % European</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Extremely Early Start</strong><br />Only 80 V start-up voltage</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Zero Export &amp; VSG</strong><br />Maximum self-consumption + grid support</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Barely Audible</strong><br />Natural cooling, &#8804; 35 dB</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Feather-Light &amp; Compact</strong><br />Only 6.35 kg, 280 &#215; 310 &#215; 184 mm, IP65</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Full Protection Suite</strong><br />Type II SPD (DC+AC), optional AFCI</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Smart Monitoring</strong><br />Wi-Fi / 4G / Bluetooth optional</div>
</div>
<div style="background: #30358C; color: white; padding: 60px 50px; border-radius: 14px; text-align: center; font-size: 26px; font-weight: 600; box-shadow: 0 15px 40px rgba(48,53,140,.5); line-height: 1.5; margin: 70px 0;">
<p>Deye SUN-2K-G04P1-EU-AM1 &#8211; The Ultra-Light 2 kW Premium Single-Phase Inverter</p>
<p style="font-size: 22px; opacity: 0.95; margin-top: 15px;">97.3 % Efficiency &#183; 80 V Start &#183; Zero Export &#183; VSG &#183; &#8804; 35 dB &#183; Only 6.35 kg &#183; IP65</p>
</div>
</div>";s:11:"products_id";i:1027;s:14:"products_price";s:8:"319.0000";s:25:"products_discount_allowed";d:0;s:12:"products_vpe";i:0;s:19:"products_vpe_status";i:0;s:18:"products_vpe_value";s:6:"0.0000";}i:1;a:21:{s:14:"products_fsk18";i:0;s:23:"products_date_available";s:19:"2025-08-31 00:00:00";s:21:"products_shippingtime";i:1;s:14:"products_model";s:19:"SUN-3K-G04P1-EU-AM1";s:15:"products_master";i:0;s:22:"products_master_status";i:0;s:12:"products_ean";s:0:"";s:13:"products_name";s:59:"SUN-3K-G04P1-EU-AM1 | Single Phase String Inverter | 1 MPPT";s:19:"products_extra_text";s:8231:"<table style="width: 100%; border-collapse: collapse; background: #fff; border-radius: 14px; overflow: hidden; box-shadow: 0 10px 35px rgba(0,0,0,.12); margin: 60px 0; font-size: 15px;">
<tbody>
<tr style="background: #30358C; color: white;"><th style="padding: 20px; text-align: left; font-weight: 600;">Parameter</th><th style="padding: 20px; text-align: left; font-weight: 600;">Value</th></tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">Single-Phase String Inverter SUN-3K-G04P1-EU-AM1</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">PV String Input Data</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Max. PV Input Power</td>
<td style="padding: 14px 20px;">3.9 kW</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Max. PV Input Voltage</td>
<td style="padding: 14px 20px;">550 V</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Start-up Voltage</td>
<td style="padding: 14px 20px;">80 V</td>
</tr>
<tr>
<td style="padding: 14px 20px;">MPPT Voltage Range</td>
<td style="padding: 14px 20px;">70&#8211;500 V</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated PV Input Voltage</td>
<td style="padding: 14px 20px;">360 V</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Max. Operating PV Input Current</td>
<td style="padding: 14px 20px;">20 A</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Max. Input Short Circuit Current</td>
<td style="padding: 14px 20px;">30 A</td>
</tr>
<tr>
<td style="padding: 14px 20px;">No. of MPP Trackers / Strings per MPP Tracker</td>
<td style="padding: 14px 20px;">1 / 1</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">AC Output Side</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated AC Output Active Power</td>
<td style="padding: 14px 20px;">3 kW</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Max. AC Output Apparent Power</td>
<td style="padding: 14px 20px;">3.3 kVA</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated AC Output Current (230 V / 220 V)</td>
<td style="padding: 14px 20px;">13.1 A / 13.7 A</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Max. AC Output Current (230 V / 220 V)</td>
<td style="padding: 14px 20px;">14.4 A / 15 A</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated Output Voltage / Range</td>
<td style="padding: 14px 20px;">220/230 V (0.85 Un &#8211; 1.1 Un)</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Grid Connection Form</td>
<td style="padding: 14px 20px;">L+N+PE</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated Grid Frequency / Range</td>
<td style="padding: 14px 20px;">50/60 Hz (45&#8211;55 / 55&#8211;65 Hz)</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Power Factor Adjustment Range</td>
<td style="padding: 14px 20px;">0.8 leading &#8211; 0.8 lagging</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Total Harmonic Distortion (THDi)</td>
<td style="padding: 14px 20px;">&lt; 3 %</td>
</tr>
<tr>
<td style="padding: 14px 20px;">DC Injection Current</td>
<td style="padding: 14px 20px;">&lt; 0.5 % In</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">Efficiency</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Max. Efficiency</td>
<td style="padding: 14px 20px;">97.5 %</td>
</tr>
<tr>
<td style="padding: 14px 20px;">European Efficiency</td>
<td style="padding: 14px 20px;">97.0 %</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">MPPT Efficiency</td>
<td style="padding: 14px 20px;">&gt; 99 %</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">Equipment Protection</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">DC Polarity Reverse Connection Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">AC Output Overcurrent Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">AC Output Overvoltage Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">AC Output Short Circuit Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Thermal Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Insulation Impedance Monitoring</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">DC Component Monitoring</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Arc Fault Circuit Interrupter (AFCI)</td>
<td style="padding: 14px 20px;">Optional</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Anti-Islanding Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Residual Current Detection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Surge Protection Level</td>
<td style="padding: 14px 20px;">Type II (DC), Type II (AC)</td>
</tr>
<tr>
<td style="padding: 14px 20px;">DC Switch</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">Interface</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Communication Interface</td>
<td style="padding: 14px 20px;">RS485 / RS232</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Monitoring Mode</td>
<td style="padding: 14px 20px;">GPRS / Wi-Fi / Bluetooth / 4G / LAN (optional)</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">General Data</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Operating Temperature Range</td>
<td style="padding: 14px 20px;">-25 &#176;C to +65 &#176;C (&gt;45 &#176;C derating)</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Permissible Ambient Humidity</td>
<td style="padding: 14px 20px;">0&#8211;100 %</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Permissible Altitude</td>
<td style="padding: 14px 20px;">2000 m</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Noise Emission</td>
<td style="padding: 14px 20px;">&#8804; 35 dB</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Ingress Protection Rating</td>
<td style="padding: 14px 20px;">IP65</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Cabinet Size (W &#215; H &#215; D)</td>
<td style="padding: 14px 20px;">280 &#215; 310 &#215; 184 mm (excl. connectors and brackets)</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Weight</td>
<td style="padding: 14px 20px;">6.35 kg</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Type of Cooling</td>
<td style="padding: 14px 20px;">Natural Cooling</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Warranty</td>
<td style="padding: 14px 20px;">5 years</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Grid Regulation</td>
<td style="padding: 14px 20px;">IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, G98, G99, VDE-AR-N 4105</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Safety EMC / Standard</td>
<td style="padding: 14px 20px;">IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1/2</td>
</tr>
</tbody>
</table>";s:17:"products_quantity";i:9999;s:16:"manufacturers_id";i:10;s:14:"products_image";s:10:"1028_0.jpg";s:15:"products_weight";s:6:"7.0000";s:26:"products_short_description";s:391:"Deye SUN-3K-G04P1-EU-AM1 3kW Single-Phase String Inverter (EU)<br /><br />Ultra-light 3 kW single-phase inverter with 97.5 % efficiency, extremely early start at 80 V, zero-export &amp; VSG function, only 6.35 kg, virtually silent (&#8804; 35 dB), IP65, Type II SPD on both sides, fully certified (G99, VDE-AR-N 4105 etc.). Perfect for small residential and compact commercial installations.";s:20:"products_description";s:3746:"<div style="font-family: 'Segoe UI',Arial,sans-serif; max-width: 1000px; margin: 0 auto; line-height: 1.7; color: #333;">
<p style="font-size: 19px; font-weight: 300; color: #222; margin-bottom: 45px;">The Deye SUN-3K-G04P1-EU-AM1 is a compact, state-of-the-art 3 kW single-phase string inverter &#8211; perfect for smaller residential homes and compact commercial systems. With a peak efficiency of 97.5 % and a European efficiency of 97.0 %, it delivers excellent performance in its class. Thanks to an extremely low start-up voltage of only 80 V, it produces power even in low-light conditions. Zero-export capability, VSG grid support, optional string-level monitoring and optional anti-PID function make it highly flexible and future-proof. Weighing just 6.35 kg, with ultra-compact dimensions of 280 &#215; 310 &#215; 184 mm, natural cooling (barely audible &#8804; 35 dB) and IP65 protection, it can be installed by one person &#8211; indoors or outdoors. Extensive communication options and full certification to all major European standards complete this outstanding package.</p>
<div style="margin: 60px 0;"><img src="https://syd-green-energy.com/files/images/syd-solar-mood-007.jpg" alt="Deye SUN-3K-G04P1-EU-AM1 3kW Single-Phase Inverter" style="width: 100%; border-radius: 14px; box-shadow: 0 12px 35px rgba(0,0,0,.15);" /></div>
<h3 style="color: #30358c; font-size: 30px; font-weight: bold; margin: 70px 0 40px; text-transform: uppercase; letter-spacing: 1.5px;">Key Advantages</h3>
<div style="display: grid; grid-template-columns: repeat(auto-fit,minmax(380px,1fr)); gap: 28px; margin-bottom: 70px;">
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Excellent Efficiency</strong><br />97.5 % peak &#183; 97.0 % European</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Extremely Early Start</strong><br />Only 80 V start-up voltage</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Zero Export &amp; VSG</strong><br />Maximum self-consumption + grid support</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Barely Audible</strong><br />Natural cooling, &#8804; 35 dB</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Feather-Light &amp; Compact</strong><br />Only 6.35 kg, 280 &#215; 310 &#215; 184 mm, IP65</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Full Protection Suite</strong><br />Type II SPD (DC+AC), optional AFCI</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Smart Monitoring</strong><br />Wi-Fi / 4G / Bluetooth optional</div>
</div>
<div style="background: #30358C; color: white; padding: 60px 50px; border-radius: 14px; text-align: center; font-size: 26px; font-weight: 600; box-shadow: 0 15px 40px rgba(48,53,140,.5); line-height: 1.5; margin: 70px 0;">
<p>Deye SUN-3K-G04P1-EU-AM1 &#8211; The Ultra-Light 3 kW Premium Single-Phase Inverter</p>
<p style="font-size: 22px; opacity: 0.95; margin-top: 15px;">97.5 % Efficiency &#183; 80 V Start &#183; Zero Export &#183; VSG &#183; &#8804; 35 dB &#183; Only 6.35 kg &#183; IP65</p>
</div>
</div>";s:11:"products_id";i:1028;s:14:"products_price";s:8:"329.0000";s:25:"products_discount_allowed";d:0;s:12:"products_vpe";i:0;s:19:"products_vpe_status";i:0;s:18:"products_vpe_value";s:6:"0.0000";}i:2;a:21:{s:14:"products_fsk18";i:0;s:23:"products_date_available";s:19:"0000-00-00 00:00:00";s:21:"products_shippingtime";i:1;s:14:"products_model";s:22:"SUN-5K-G06P3-EU-AM2-P1";s:15:"products_master";i:0;s:22:"products_master_status";i:0;s:12:"products_ean";s:0:"";s:13:"products_name";s:61:"SUN-5K-G06P3-EU-AM2-P1 | Three Phase String Inverter | 2 MPPT";s:19:"products_extra_text";s:9012:"<table style="width: 100%; border-collapse: collapse; background: #fff; border-radius: 14px; overflow: hidden; box-shadow: 0 10px 35px rgba(0,0,0,.12); margin: 60px 0; font-size: 15px;">
<tbody>
<tr style="background: #30358C; color: white;"><th style="padding: 20px; text-align: left; font-weight: 600;">Parameter</th><th style="padding: 20px; text-align: left; font-weight: 600;">Value</th></tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">String Inverter Model SUN-5K-G06P3-EU-AM2-P1</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">PV String Input Data</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Max. PV Input Power</td>
<td style="padding: 14px 20px;">7.5 kW</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Max. PV Input Voltage</td>
<td style="padding: 14px 20px;">1100 V</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Start-up Voltage</td>
<td style="padding: 14px 20px;">140 V</td>
</tr>
<tr>
<td style="padding: 14px 20px;">MPPT Voltage Range</td>
<td style="padding: 14px 20px;">120&#8211;1000 V</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated PV Input Voltage</td>
<td style="padding: 14px 20px;">600 V</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Max. Operating PV Input Current</td>
<td style="padding: 14px 20px;">20 + 20 A</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Max. Input Short Circuit Current</td>
<td style="padding: 14px 20px;">30 + 30 A</td>
</tr>
<tr>
<td style="padding: 14px 20px;">No. of MPP Trackers / Strings per MPP Tracker</td>
<td style="padding: 14px 20px;">2 / 1+1</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">AC Output Side</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated AC Output Active Power</td>
<td style="padding: 14px 20px;">5 kW</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Max. AC Output Apparent Power</td>
<td style="padding: 14px 20px;">5.5 kVA</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated AC Output Current (400 V / 380 V)</td>
<td style="padding: 14px 20px;">7.3 A / 7.6 A</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Max. AC Output Current (400 V / 380 V)</td>
<td style="padding: 14px 20px;">8 A / 8.4 A</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated Output Voltage / Range</td>
<td style="padding: 14px 20px;">220/380 V, 230/400 V (0.85 Un &#8211; 1.1 Un)</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Grid Connection Form</td>
<td style="padding: 14px 20px;">3L/N/PE</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated Grid Frequency / Range</td>
<td style="padding: 14px 20px;">50/60 Hz (45&#8211;55 / 55&#8211;65 Hz)</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Power Factor Adjustment Range</td>
<td style="padding: 14px 20px;">0.8 leading &#8211; 0.8 lagging</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Total Harmonic Distortion (THDi)</td>
<td style="padding: 14px 20px;">&lt; 3 %</td>
</tr>
<tr>
<td style="padding: 14px 20px;">DC Injection Current</td>
<td style="padding: 14px 20px;">&lt; 0.5 % In</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">Efficiency</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Max. Efficiency</td>
<td style="padding: 14px 20px;">98.2 %</td>
</tr>
<tr>
<td style="padding: 14px 20px;">European Efficiency</td>
<td style="padding: 14px 20px;">97.6 %</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">MPPT Efficiency</td>
<td style="padding: 14px 20px;">&gt; 99 %</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">Equipment Protection</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">DC Polarity Reverse Connection Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">AC Output Overcurrent Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">AC Output Overvoltage Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">AC Output Short Circuit Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Thermal Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">DC Terminal Insulation Impedance Monitoring</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">DC Component Monitoring</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Arc Fault Circuit Interrupter (AFCI)</td>
<td style="padding: 14px 20px;">Optional</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Ground Fault Current Monitoring</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Power Network Monitoring</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Island Protection Monitoring</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Earth Fault Detection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Overvoltage Load Drop Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Residual Current (RCD) Detection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Surge Protection Level</td>
<td style="padding: 14px 20px;">Type II (DC), Type II (AC)</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">Interface</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Communication Interface</td>
<td style="padding: 14px 20px;">RS485 / RS232</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Monitoring Mode</td>
<td style="padding: 14px 20px;">GPRS / Wi-Fi / Bluetooth / 4G / LAN (optional)</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">General Data</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Operating Temperature Range</td>
<td style="padding: 14px 20px;">-25 &#176;C to +60 &#176;C (&gt;45 &#176;C derating)</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Permissible Ambient Humidity</td>
<td style="padding: 14px 20px;">0&#8211;100 %</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Permissible Altitude</td>
<td style="padding: 14px 20px;">4000 m</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Noise Emission</td>
<td style="padding: 14px 20px;">&lt; 45 dB</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Ingress Protection Rating</td>
<td style="padding: 14px 20px;">IP65</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Inverter Topology</td>
<td style="padding: 14px 20px;">Non-Isolated</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Over Voltage Category</td>
<td style="padding: 14px 20px;">OVC II (DC), OVC III (AC)</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Cabinet Size (W &#215; H &#215; D)</td>
<td style="padding: 14px 20px;">283 &#215; 463 &#215; 178 mm (excl. connectors and brackets)</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Weight</td>
<td style="padding: 14px 20px;">11 kg</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Type of Cooling</td>
<td style="padding: 14px 20px;">Natural Cooling</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Warranty</td>
<td style="padding: 14px 20px;">5 years</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Grid Regulation</td>
<td style="padding: 14px 20px;">IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G98, G99, VDE-AR-N 4105</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Safety EMC / Standard</td>
<td style="padding: 14px 20px;">IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1/2</td>
</tr>
</tbody>
</table>";s:17:"products_quantity";i:9999;s:16:"manufacturers_id";i:10;s:14:"products_image";s:10:"1029_0.jpg";s:15:"products_weight";s:7:"11.0000";s:26:"products_short_description";s:398:"Deye SUN-5K-G06P3-EU-AM2-P1 5kW Three-Phase String Inverter (EU)<br /><br />Ultra-light and completely silent 5 kW inverter with 98.2 % efficiency, 2 MPPT (120&#8211;1000 V), zero-export &amp; VSG function, optional string monitoring, only 11 kg, natural cooling. IP65, Type II SPD both sides, fully certified (G99, VDE-AR-N 4105 etc.). Ideal for smaller residential and compact commercial systems.";s:20:"products_description";s:3907:"<div style="font-family: 'Segoe UI',Arial,sans-serif; max-width: 1000px; margin: 0 auto; line-height: 1.7; color: #333;">
<p style="font-size: 19px; font-weight: 300; color: #222; margin-bottom: 45px;">The Deye SUN-5K-G06P3-EU-AM2-P1 is a state-of-the-art 5 kW three-phase string inverter of the latest generation &#8211; ideal for smaller residential homes and compact commercial installations. With a peak efficiency of 98.2 % and a European efficiency of 97.6 %, it delivers outstanding performance. Two independent MPPTs with an extremely wide voltage range of 120&#8211;1000 V and a very low start-up voltage of only 140 V guarantee maximum yield even in diffuse light conditions. Zero-export capability, integrated VSG technology for grid support, optional string-level monitoring and optional anti-PID function make this inverter future-proof and highly flexible. Weighing just 11 kg, with compact dimensions of 283 &#215; 463 &#215; 178 mm, natural cooling (completely silent) and IP65 protection, it can be installed by one person &#8211; indoors or outdoors. Extensive communication options and full certification to all major European standards complete this top-class package.</p>
<div style="margin: 60px 0;"><img src="https://syd-green-energy.com/files/images/syd-solar-mood-008.jpg" alt="Deye SUN-5K-G06P3-EU-AM2-P1 5kW String Inverter" style="width: 100%; border-radius: 14px; box-shadow: 0 12px 35px rgba(0,0,0,.15);" /></div>
<h3 style="color: #30358c; font-size: 30px; font-weight: bold; margin: 70px 0 40px; text-transform: uppercase; letter-spacing: 1.5px;">Key Advantages</h3>
<div style="display: grid; grid-template-columns: repeat(auto-fit,minmax(380px,1fr)); gap: 28px; margin-bottom: 70px;">
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Excellent Efficiency</strong><br />98.2 % peak &#183; 97.6 % European &#8211; very high yield.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Extremely Low Start-Up</strong><br />Only 140 V start, 120&#8211;1000 V MPPT range.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Zero Export &amp; VSG</strong><br />Perfect for export-limited regions + grid support.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Completely Silent</strong><br />Natural cooling, &lt; 45 dB.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Ultra-Light &amp; Compact</strong><br />Only 11 kg, 283 &#215; 463 &#215; 178 mm, IP65.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Full Protection Suite</strong><br />Type II SPD (DC+AC), optional AFCI &amp; anti-PID.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Smart Monitoring</strong><br />Optional string monitoring, Wi-Fi/4G/LAN.</div>
</div>
<div style="background: #30358C; color: white; padding: 60px 50px; border-radius: 14px; text-align: center; font-size: 26px; font-weight: 600; box-shadow: 0 15px 40px rgba(48,53,140,.5); line-height: 1.5; margin: 70px 0;">
<p>Deye SUN-5K-G06P3-EU-AM2-P1 &#8211; The Silent 5 kW Premium String Inverter</p>
<p style="font-size: 22px; opacity: 0.95; margin-top: 15px;">98.2 % Efficiency &#183; 2 MPPT &#183; Zero Export &#183; VSG &#183; Silent &#183; Only 11 kg &#183; IP65</p>
</div>
</div>";s:11:"products_id";i:1029;s:14:"products_price";s:8:"379.0000";s:25:"products_discount_allowed";d:0;s:12:"products_vpe";i:0;s:19:"products_vpe_status";i:0;s:18:"products_vpe_value";s:6:"0.0000";}i:3;a:21:{s:14:"products_fsk18";i:0;s:23:"products_date_available";s:19:"2025-08-31 00:00:00";s:21:"products_shippingtime";i:1;s:14:"products_model";s:22:"SUN-6K-G06P3-EU-AM2-P1";s:15:"products_master";i:0;s:22:"products_master_status";i:0;s:12:"products_ean";s:0:"";s:13:"products_name";s:61:"SUN-6K-G06P3-EU-AM2-P1 | Three Phase String Inverter | 2 MPPT";s:19:"products_extra_text";s:9011:"<table style="width: 100%; border-collapse: collapse; background: #fff; border-radius: 14px; overflow: hidden; box-shadow: 0 10px 35px rgba(0,0,0,.12); margin: 60px 0; font-size: 15px;">
<tbody>
<tr style="background: #30358C; color: white;"><th style="padding: 20px; text-align: left; font-weight: 600;">Parameter</th><th style="padding: 20px; text-align: left; font-weight: 600;">Value</th></tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">String Inverter Model SUN-6K-G06P3-EU-AM2-P1</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">PV String Input Data</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Max. PV Input Power</td>
<td style="padding: 14px 20px;">9 kW</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Max. PV Input Voltage</td>
<td style="padding: 14px 20px;">1100 V</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Start-up Voltage</td>
<td style="padding: 14px 20px;">140 V</td>
</tr>
<tr>
<td style="padding: 14px 20px;">MPPT Voltage Range</td>
<td style="padding: 14px 20px;">120&#8211;1000 V</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated PV Input Voltage</td>
<td style="padding: 14px 20px;">600 V</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Max. Operating PV Input Current</td>
<td style="padding: 14px 20px;">20 + 20 A</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Max. Input Short Circuit Current</td>
<td style="padding: 14px 20px;">30 + 30 A</td>
</tr>
<tr>
<td style="padding: 14px 20px;">No. of MPP Trackers / Strings per MPP Tracker</td>
<td style="padding: 14px 20px;">2 / 1+1</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">AC Output Side</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated AC Output Active Power</td>
<td style="padding: 14px 20px;">6 kW</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Max. AC Output Apparent Power</td>
<td style="padding: 14px 20px;">6.6 kVA</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated AC Output Current (400 V / 380 V)</td>
<td style="padding: 14px 20px;">8.7 A / 9.1 A</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Max. AC Output Current (400 V / 380 V)</td>
<td style="padding: 14px 20px;">9.6 A / 10 A</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated Output Voltage / Range</td>
<td style="padding: 14px 20px;">220/380 V, 230/400 V (0.85 Un &#8211; 1.1 Un)</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Grid Connection Form</td>
<td style="padding: 14px 20px;">3L/N/PE</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated Grid Frequency / Range</td>
<td style="padding: 14px 20px;">50/60 Hz (45&#8211;55 / 55&#8211;65 Hz)</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Power Factor Adjustment Range</td>
<td style="padding: 14px 20px;">0.8 leading &#8211; 0.8 lagging</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Total Harmonic Distortion (THDi)</td>
<td style="padding: 14px 20px;">&lt; 3 %</td>
</tr>
<tr>
<td style="padding: 14px 20px;">DC Injection Current</td>
<td style="padding: 14px 20px;">&lt; 0.5 % In</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">Efficiency</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Max. Efficiency</td>
<td style="padding: 14px 20px;">98.2 %</td>
</tr>
<tr>
<td style="padding: 14px 20px;">European Efficiency</td>
<td style="padding: 14px 20px;">97.6 %</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">MPPT Efficiency</td>
<td style="padding: 14px 20px;">&gt; 99 %</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">Equipment Protection</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">DC Polarity Reverse Connection Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">AC Output Overcurrent Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">AC Output Overvoltage Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">AC Output Short Circuit Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Thermal Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">DC Terminal Insulation Impedance Monitoring</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">DC Component Monitoring</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Arc Fault Circuit Interrupter (AFCI)</td>
<td style="padding: 14px 20px;">Optional</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Ground Fault Current Monitoring</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Power Network Monitoring</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Island Protection Monitoring</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Earth Fault Detection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Overvoltage Load Drop Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Residual Current (RCD) Detection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Surge Protection Level</td>
<td style="padding: 14px 20px;">Type II (DC), Type II (AC)</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">Interface</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Communication Interface</td>
<td style="padding: 14px 20px;">RS485 / RS232</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Monitoring Mode</td>
<td style="padding: 14px 20px;">GPRS / Wi-Fi / Bluetooth / 4G / LAN (optional)</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">General Data</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Operating Temperature Range</td>
<td style="padding: 14px 20px;">-25 &#176;C to +60 &#176;C (&gt;45 &#176;C derating)</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Permissible Ambient Humidity</td>
<td style="padding: 14px 20px;">0&#8211;100 %</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Permissible Altitude</td>
<td style="padding: 14px 20px;">4000 m</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Noise Emission</td>
<td style="padding: 14px 20px;">&lt; 45 dB</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Ingress Protection Rating</td>
<td style="padding: 14px 20px;">IP65</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Inverter Topology</td>
<td style="padding: 14px 20px;">Non-Isolated</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Over Voltage Category</td>
<td style="padding: 14px 20px;">OVC II (DC), OVC III (AC)</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Cabinet Size (W &#215; H &#215; D)</td>
<td style="padding: 14px 20px;">283 &#215; 463 &#215; 178 mm (excl. connectors and brackets)</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Weight</td>
<td style="padding: 14px 20px;">11 kg</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Type of Cooling</td>
<td style="padding: 14px 20px;">Natural Cooling</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Warranty</td>
<td style="padding: 14px 20px;">5 years</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Grid Regulation</td>
<td style="padding: 14px 20px;">IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G98, G99, VDE-AR-N 4105</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Safety EMC / Standard</td>
<td style="padding: 14px 20px;">IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1/2</td>
</tr>
</tbody>
</table>";s:17:"products_quantity";i:9999;s:16:"manufacturers_id";i:10;s:14:"products_image";s:10:"1030_0.jpg";s:15:"products_weight";s:7:"11.0000";s:26:"products_short_description";s:396:"Deye SUN-6K-G06P3-EU-AM2-P1 6kW Three-Phase String Inverter (EU)<br /><br />Ultra-light and completely silent 6 kW inverter with 98.2 % efficiency, 2 MPPT (120&#8211;1000 V), zero-export &amp; VSG function, optional string monitoring, only 11 kg, natural cooling. IP65, Type II SPD both sides, fully certified (G99, VDE-AR-N 4105 etc.). Perfect for residential and small commercial installations.";s:20:"products_description";s:3910:"<div style="font-family: 'Segoe UI',Arial,sans-serif; max-width: 1000px; margin: 0 auto; line-height: 1.7; color: #333;">
<p style="font-size: 19px; font-weight: 300; color: #222; margin-bottom: 45px;">The Deye SUN-6K-G06P3-EU-AM2-P1 is a state-of-the-art 6 kW three-phase string inverter of the latest generation &#8211; the perfect choice for residential homes and small commercial solar systems. With a peak efficiency of 98.2 % and a European efficiency of 97.6 %, it delivers outstanding performance. Two independent MPPTs with an extremely wide voltage range of 120&#8211;1000 V and a very low start-up voltage of only 140 V guarantee maximum yield even in diffuse light conditions. Zero-export capability, integrated VSG technology for grid support, optional string-level monitoring and optional anti-PID function make this inverter future-proof and highly flexible. Weighing just 11 kg, with compact dimensions of 283 &#215; 463 &#215; 178 mm, natural cooling (completely silent) and IP65 protection, it can be installed by one person &#8211; indoors or outdoors. Extensive communication options and full certification to all major European standards complete this top-class package.</p>
<div style="margin: 60px 0;"><img src="https://syd-green-energy.com/files/images/syd-solar-mood-008.jpg" alt="Deye SUN-6K-G06P3-EU-AM2-P1 6kW String Inverter" style="width: 100%; border-radius: 14px; box-shadow: 0 12px 35px rgba(0,0,0,.15);" /></div>
<h3 style="color: #30358c; font-size: 30px; font-weight: bold; margin: 70px 0 40px; text-transform: uppercase; letter-spacing: 1.5px;">Key Advantages</h3>
<div style="display: grid; grid-template-columns: repeat(auto-fit,minmax(380px,1fr)); gap: 28px; margin-bottom: 70px;">
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Excellent Efficiency</strong><br />98.2 % peak &#183; 97.6 % European &#8211; very high yield.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Extremely Low Start-Up</strong><br />Only 140 V start, 120&#8211;1000 V MPPT range.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Zero Export &amp; VSG</strong><br />Perfect for export-limited regions + grid support.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Completely Silent</strong><br />Natural cooling, &lt; 45 dB.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Ultra-Light &amp; Compact</strong><br />Only 11 kg, 283 &#215; 463 &#215; 178 mm, IP65.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Full Protection Suite</strong><br />Type II SPD (DC+AC), optional AFCI &amp; anti-PID.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Smart Monitoring</strong><br />Optional string monitoring, Wi-Fi/4G/LAN.</div>
</div>
<div style="background: #30358C; color: white; padding: 60px 50px; border-radius: 14px; text-align: center; font-size: 26px; font-weight: 600; box-shadow: 0 15px 40px rgba(48,53,140,.5); line-height: 1.5; margin: 70px 0;">
<p>Deye SUN-6K-G06P3-EU-AM2-P1 &#8211; The Silent 6 kW Premium String Inverter</p>
<p style="font-size: 22px; opacity: 0.95; margin-top: 15px;">98.2 % Efficiency &#183; 2 MPPT &#183; Zero Export &#183; VSG &#183; Silent &#183; Only 11 kg &#183; IP65</p>
</div>
</div>";s:11:"products_id";i:1030;s:14:"products_price";s:8:"500.0000";s:25:"products_discount_allowed";d:0;s:12:"products_vpe";i:0;s:19:"products_vpe_status";i:0;s:18:"products_vpe_value";s:6:"0.0000";}i:4;a:21:{s:14:"products_fsk18";i:0;s:23:"products_date_available";s:19:"0000-00-00 00:00:00";s:21:"products_shippingtime";i:1;s:14:"products_model";s:22:"SUN-8K-G06P3-EU-AM2-P1";s:15:"products_master";i:0;s:22:"products_master_status";i:0;s:12:"products_ean";s:0:"";s:13:"products_name";s:61:"SUN-8K-G06P3-EU-AM2-P1 | Three Phase String Inverter | 2 MPPT";s:19:"products_extra_text";s:7017:"<table style="width: 100%; border-collapse: collapse; background: #fff; border-radius: 14px; overflow: hidden; box-shadow: 0 10px 35px rgba(0,0,0,.12); margin: 60px 0; font-size: 15px;">
<tbody>
<tr style="background: #30358C; color: white;"><th style="padding: 20px; text-align: left; font-weight: 600;">Parameter</th><th style="padding: 20px; text-align: left; font-weight: 600;">Value</th></tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">String Inverter Model SUN-8K-G06P3-EU-AM2-P1</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">PV String Input Data</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Max. PV Input Power</td>
<td style="padding: 14px 20px;">12 kW</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Max. PV Input Voltage</td>
<td style="padding: 14px 20px;">1100 V</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Start-up Voltage</td>
<td style="padding: 14px 20px;">140 V</td>
</tr>
<tr>
<td style="padding: 14px 20px;">MPPT Voltage Range</td>
<td style="padding: 14px 20px;">120&#8211;1000 V</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated PV Input Voltage</td>
<td style="padding: 14px 20px;">600 V</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Max. Operating PV Input Current</td>
<td style="padding: 14px 20px;">20 + 20 A</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Max. Input Short Circuit Current</td>
<td style="padding: 14px 20px;">30 + 30 A</td>
</tr>
<tr>
<td style="padding: 14px 20px;">No. of MPP Trackers / Strings per MPP Tracker</td>
<td style="padding: 14px 20px;">2 / 1+1</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">AC Output Side</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated AC Output Active Power</td>
<td style="padding: 14px 20px;">8 kW</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Max. AC Output Apparent Power</td>
<td style="padding: 14px 20px;">8.8 kVA</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated AC Output Current (400 V / 380 V)</td>
<td style="padding: 14px 20px;">11.6 A / 12.2 A</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Max. AC Output Current (400 V / 380 V)</td>
<td style="padding: 14px 20px;">12.8 A / 13.4 A</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated Output Voltage / Range</td>
<td style="padding: 14px 20px;">220/380 V, 230/400 V (0.85 Un &#8211; 1.1 Un)</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Grid Connection Form</td>
<td style="padding: 14px 20px;">3L/N/PE</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated Grid Frequency / Range</td>
<td style="padding: 14px 20px;">50/60 Hz (45&#8211;55 / 55&#8211;65 Hz)</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Power Factor Adjustment Range</td>
<td style="padding: 14px 20px;">0.8 leading &#8211; 0.8 lagging</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Total Harmonic Distortion (THDi)</td>
<td style="padding: 14px 20px;">&lt; 3 %</td>
</tr>
<tr>
<td style="padding: 14px 20px;">DC Injection Current</td>
<td style="padding: 14px 20px;">&lt; 0.5 % In</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">Efficiency</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Max. Efficiency</td>
<td style="padding: 14px 20px;">98.3 %</td>
</tr>
<tr>
<td style="padding: 14px 20px;">European Efficiency</td>
<td style="padding: 14px 20px;">97.8 %</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">MPPT Efficiency</td>
<td style="padding: 14px 20px;">&gt; 99 %</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">Equipment Protection</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">DC Polarity Reverse Connection Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">AC Output Overcurrent Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">AC Output Overvoltage Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">AC Output Short Circuit Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Thermal Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">DC Terminal Insulation Impedance Monitoring</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">DC Component Monitoring</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Arc Fault Circuit Interrupter (AFCI)</td>
<td style="padding: 14px 20px;">Optional</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Ground Fault Current Monitoring</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Power Network Monitoring</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Island Protection Monitoring</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Earth Fault Detection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Overvoltage Load Drop Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Residual Current (RCD) Detection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Surge Protection Level</td>
<td style="padding: 14px 20px;">Type II (DC), Type II (AC)</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">Interface</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Communication Interface</td>
<td style="padding: 14px 20px;">RS485 / RS232</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Monitoring Mode</td>
<td style="padding: 14px 20px;">GPRS / Wi-Fi / Bluetooth / 4G / LAN (optional)</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">General Data</td>
</tr>
</tbody>
</table>";s:17:"products_quantity";i:9999;s:16:"manufacturers_id";i:10;s:14:"products_image";s:10:"1031_0.jpg";s:15:"products_weight";s:7:"11.0000";s:26:"products_short_description";s:394:"Deye SUN-8K-G06P3-EU-AM2-P1 8kW Three-Phase String Inverter (EU)<br /><br />Ultra-light and completely silent 8 kW inverter with 98.3 % efficiency, 2 MPPT (120&#8211;1000 V), zero-export &amp; VSG function, optional string monitoring, only 11 kg, natural cooling. IP65, Type II SPD both sides, fully certified (G99, VDE-AR-N 4105 etc.). Ideal for residential and small commercial installations.";s:20:"products_description";s:3901:"<div style="font-family: 'Segoe UI',Arial,sans-serif; max-width: 1000px; margin: 0 auto; line-height: 1.7; color: #333;">
<p style="font-size: 19px; font-weight: 300; color: #222; margin-bottom: 45px;">The Deye SUN-8K-G06P3-EU-AM2-P1 is a state-of-the-art 8 kW three-phase string inverter of the latest generation &#8211; perfect for residential homes and smaller commercial solar systems. With a peak efficiency of 98.3 % and a European efficiency of 97.8 %, it delivers outstanding performance. Two independent MPPTs with an extremely wide voltage range of 120&#8211;1000 V and a very low start-up voltage of only 140 V guarantee maximum yield even in diffuse light conditions. Zero-export capability, integrated VSG technology for grid support, optional string-level monitoring and optional anti-PID function make this inverter future-proof and highly flexible. Weighing just 11 kg, with compact dimensions of 283 &#215; 463 &#215; 178 mm, natural cooling (completely silent) and IP65 protection, it can be installed by one person &#8211; indoors or outdoors. Extensive communication options and full certification to all major European standards complete this top-class package.</p>
<div style="margin: 60px 0;"><img src="https://syd-green-energy.com/files/images/syd-solar-mood-008.jpg" alt="Deye SUN-8K-G06P3-EU-AM2-P1 8kW String Inverter" style="width: 100%; border-radius: 14px; box-shadow: 0 12px 35px rgba(0,0,0,.15);" /></div>
<h3 style="color: #30358c; font-size: 30px; font-weight: bold; margin: 70px 0 40px; text-transform: uppercase; letter-spacing: 1.5px;">Key Advantages</h3>
<div style="display: grid; grid-template-columns: repeat(auto-fit,minmax(380px,1fr)); gap: 28px; margin-bottom: 70px;">
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Excellent Efficiency</strong><br />98.3 % peak &#183; 97.8 % European &#8211; very high yield.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Extremely Low Start-Up</strong><br />Only 140 V start, 120&#8211;1000 V MPPT range.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Zero Export &amp; VSG</strong><br />Perfect for export-limited regions + grid support.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Completely Silent</strong><br />Natural cooling, &lt; 45 dB.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Ultra-Light &amp; Compact</strong><br />Only 11 kg, 283 &#215; 463 &#215; 178 mm, IP65.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Full Protection Suite</strong><br />Type II SPD (DC+AC), optional AFCI &amp; anti-PID.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Smart Monitoring</strong><br />Optional string monitoring, Wi-Fi/4G/LAN.</div>
</div>
<div style="background: #30358C; color: white; padding: 60px 50px; border-radius: 14px; text-align: center; font-size: 26px; font-weight: 600; box-shadow: 0 15px 40px rgba(48,53,140,.5); line-height: 1.5; margin: 70px 0;">
<p>Deye SUN-8K-G06P3-EU-AM2-P1 &#8211; The Silent 8 kW Premium String Inverter</p>
<p style="font-size: 22px; opacity: 0.95; margin-top: 15px;">98.3 % Efficiency &#183; 2 MPPT &#183; Zero Export &#183; VSG &#183; Silent &#183; Only 11 kg &#183; IP65</p>
</div>
</div>";s:11:"products_id";i:1031;s:14:"products_price";s:8:"510.0000";s:25:"products_discount_allowed";d:0;s:12:"products_vpe";i:0;s:19:"products_vpe_status";i:0;s:18:"products_vpe_value";s:6:"0.0000";}i:5;a:21:{s:14:"products_fsk18";i:0;s:23:"products_date_available";s:19:"0000-00-00 00:00:00";s:21:"products_shippingtime";i:1;s:14:"products_model";s:23:"SUN-10K-G06P3-EU-AM2-P1";s:15:"products_master";i:0;s:22:"products_master_status";i:0;s:12:"products_ean";s:0:"";s:13:"products_name";s:62:"SUN-10K-G06P3-EU-AM2-P1 | Three Phase String Inverter | 2 MPPT";s:19:"products_extra_text";s:9016:"<table style="width: 100%; border-collapse: collapse; background: #fff; border-radius: 14px; overflow: hidden; box-shadow: 0 10px 35px rgba(0,0,0,.12); margin: 60px 0; font-size: 15px;">
<tbody>
<tr style="background: #30358C; color: white;"><th style="padding: 20px; text-align: left; font-weight: 600;">Parameter</th><th style="padding: 20px; text-align: left; font-weight: 600;">Value</th></tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">String Inverter Model SUN-10K-G06P3-EU-AM2-P1</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">PV String Input Data</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Max. PV Input Power</td>
<td style="padding: 14px 20px;">15 kW</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Max. PV Input Voltage</td>
<td style="padding: 14px 20px;">1100 V</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Start-up Voltage</td>
<td style="padding: 14px 20px;">140 V</td>
</tr>
<tr>
<td style="padding: 14px 20px;">MPPT Voltage Range</td>
<td style="padding: 14px 20px;">120&#8211;1000 V</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated PV Input Voltage</td>
<td style="padding: 14px 20px;">600 V</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Max. Operating PV Input Current</td>
<td style="padding: 14px 20px;">20 + 20 A</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Max. Input Short Circuit Current</td>
<td style="padding: 14px 20px;">30 + 30 A</td>
</tr>
<tr>
<td style="padding: 14px 20px;">No. of MPP Trackers / Strings per MPP Tracker</td>
<td style="padding: 14px 20px;">2 / 1+1</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">AC Output Side</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated AC Output Active Power</td>
<td style="padding: 14px 20px;">10 kW</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Max. AC Output Apparent Power</td>
<td style="padding: 14px 20px;">11 kVA</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated AC Output Current (400 V / 380 V)</td>
<td style="padding: 14px 20px;">14.5 A / 15.2 A</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Max. AC Output Current (400 V / 380 V)</td>
<td style="padding: 14px 20px;">16 A / 16.7 A</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated Output Voltage / Range</td>
<td style="padding: 14px 20px;">220/380 V, 230/400 V (0.85 Un &#8211; 1.1 Un)</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Grid Connection Form</td>
<td style="padding: 14px 20px;">3L/N/PE</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated Grid Frequency / Range</td>
<td style="padding: 14px 20px;">50/60 Hz (45&#8211;55 / 55&#8211;65 Hz)</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Power Factor Adjustment Range</td>
<td style="padding: 14px 20px;">0.8 leading &#8211; 0.8 lagging</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Total Harmonic Distortion (THDi)</td>
<td style="padding: 14px 20px;">&lt; 3 %</td>
</tr>
<tr>
<td style="padding: 14px 20px;">DC Injection Current</td>
<td style="padding: 14px 20px;">&lt; 0.5 % In</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">Efficiency</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Max. Efficiency</td>
<td style="padding: 14px 20px;">98.3 %</td>
</tr>
<tr>
<td style="padding: 14px 20px;">European Efficiency</td>
<td style="padding: 14px 20px;">97.8 %</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">MPPT Efficiency</td>
<td style="padding: 14px 20px;">&gt; 99 %</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">Equipment Protection</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">DC Polarity Reverse Connection Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">AC Output Overcurrent Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">AC Output Overvoltage Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">AC Output Short Circuit Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Thermal Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">DC Terminal Insulation Impedance Monitoring</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">DC Component Monitoring</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Arc Fault Circuit Interrupter (AFCI)</td>
<td style="padding: 14px 20px;">Optional</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Ground Fault Current Monitoring</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Power Network Monitoring</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Island Protection Monitoring</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Earth Fault Detection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Overvoltage Load Drop Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Residual Current (RCD) Detection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Surge Protection Level</td>
<td style="padding: 14px 20px;">Type II (DC), Type II (AC)</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">Interface</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Communication Interface</td>
<td style="padding: 14px 20px;">RS485 / RS232</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Monitoring Mode</td>
<td style="padding: 14px 20px;">GPRS / Wi-Fi / Bluetooth / 4G / LAN (optional)</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">General Data</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Operating Temperature Range</td>
<td style="padding: 14px 20px;">-25 &#176;C to +60 &#176;C (&gt;45 &#176;C derating)</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Permissible Ambient Humidity</td>
<td style="padding: 14px 20px;">0&#8211;100 %</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Permissible Altitude</td>
<td style="padding: 14px 20px;">4000 m</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Noise Emission</td>
<td style="padding: 14px 20px;">&lt; 45 dB</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Ingress Protection Rating</td>
<td style="padding: 14px 20px;">IP65</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Inverter Topology</td>
<td style="padding: 14px 20px;">Non-Isolated</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Over Voltage Category</td>
<td style="padding: 14px 20px;">OVC II (DC), OVC III (AC)</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Cabinet Size (W &#215; H &#215; D)</td>
<td style="padding: 14px 20px;">283 &#215; 463 &#215; 178 mm (excl. connectors and brackets)</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Weight</td>
<td style="padding: 14px 20px;">11 kg</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Type of Cooling</td>
<td style="padding: 14px 20px;">Natural Cooling</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Warranty</td>
<td style="padding: 14px 20px;">5 years</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Grid Regulation</td>
<td style="padding: 14px 20px;">IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G98, G99, VDE-AR-N 4105</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Safety EMC / Standard</td>
<td style="padding: 14px 20px;">IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1/2</td>
</tr>
</tbody>
</table>";s:17:"products_quantity";i:9999;s:16:"manufacturers_id";i:10;s:14:"products_image";s:10:"1032_0.jpg";s:15:"products_weight";s:7:"11.0000";s:26:"products_short_description";s:393:"Deye SUN-10K-G06P3-EU-AM2-P1 10kW Three-Phase String Inverter (EU)<br /><br />Ultra-light and completely silent 10 kW inverter with 98.3 % efficiency, 2 MPPT (120&#8211;1000 V), zero-export &amp; VSG function, optional string monitoring, only 11 kg, natural cooling. IP65, Type II SPD both sides, fully certified (G99, VDE-AR-N 4105 etc.). Perfect for residential and small commercial systems.";s:20:"products_description";s:3899:"<div style="font-family: 'Segoe UI',Arial,sans-serif; max-width: 1000px; margin: 0 auto; line-height: 1.7; color: #333;">
<p style="font-size: 19px; font-weight: 300; color: #222; margin-bottom: 45px;">The Deye SUN-10K-G06P3-EU-AM2-P1 is a state-of-the-art 10 kW three-phase string inverter of the latest generation &#8211; ideal for residential and smaller commercial solar systems. With a peak efficiency of 98.3 % and a European efficiency of 97.8 %, it delivers outstanding performance. Two independent MPPTs with an extremely wide voltage range of 120&#8211;1000 V and a very low start-up voltage of only 140 V guarantee maximum yield even in diffuse light conditions. Zero-export capability, integrated VSG technology for grid support, optional string-level monitoring and optional anti-PID function make this inverter future-proof and highly flexible. Weighing just 11 kg, with compact dimensions of 283 &#215; 463 &#215; 178 mm, natural cooling (completely silent) and IP65 protection, it can be installed by one person &#8211; indoors or outdoors. Extensive communication options and full certification to all major European standards complete this top-class package.</p>
<div style="margin: 60px 0;"><img src="https://syd-green-energy.com/files/images/syd-solar-mood-008.jpg" alt="Deye SUN-10K-G06P3-EU-AM2-P1 10kW String Inverter" style="width: 100%; border-radius: 14px; box-shadow: 0 12px 35px rgba(0,0,0,.15);" /></div>
<h3 style="color: #30358c; font-size: 30px; font-weight: bold; margin: 70px 0 40px; text-transform: uppercase; letter-spacing: 1.5px;">Key Advantages</h3>
<div style="display: grid; grid-template-columns: repeat(auto-fit,minmax(380px,1fr)); gap: 28px; margin-bottom: 70px;">
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Excellent Efficiency</strong><br />98.3 % peak &#183; 97.8 % European &#8211; very high yield.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Extremely Low Start-Up</strong><br />Only 140 V start, 120&#8211;1000 V MPPT range.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Zero Export &amp; VSG</strong><br />Perfect for export-limited regions + grid support.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Completely Silent</strong><br />Natural cooling, &lt; 45 dB.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Ultra-Light &amp; Compact</strong><br />Only 11 kg, 283 &#215; 463 &#215; 178 mm, IP65.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Full Protection Suite</strong><br />Type II SPD (DC+AC), optional AFCI &amp; anti-PID.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Smart Monitoring</strong><br />Optional string monitoring, Wi-Fi/4G/LAN.</div>
</div>
<div style="background: #30358C; color: white; padding: 60px 50px; border-radius: 14px; text-align: center; font-size: 26px; font-weight: 600; box-shadow: 0 15px 40px rgba(48,53,140,.5); line-height: 1.5; margin: 70px 0;">
<p>Deye SUN-10K-G06P3-EU-AM2-P1 &#8211; The Silent 10 kW Premium String Inverter</p>
<p style="font-size: 22px; opacity: 0.95; margin-top: 15px;">98.3 % Efficiency &#183; 2 MPPT &#183; Zero Export &#183; VSG &#183; Silent &#183; Only 11 kg &#183; IP65</p>
</div>
</div>";s:11:"products_id";i:1032;s:14:"products_price";s:8:"520.0000";s:25:"products_discount_allowed";d:0;s:12:"products_vpe";i:0;s:19:"products_vpe_status";i:0;s:18:"products_vpe_value";s:6:"0.0000";}i:6;a:21:{s:14:"products_fsk18";i:0;s:23:"products_date_available";s:19:"0000-00-00 00:00:00";s:21:"products_shippingtime";i:1;s:14:"products_model";s:23:"SUN-12K-G06P3-EU-AM2-P1";s:15:"products_master";i:0;s:22:"products_master_status";i:0;s:12:"products_ean";s:0:"";s:13:"products_name";s:62:"SUN-12K-G06P3-EU-AM2-P1 | Three Phase String Inverter | 2 MPPT";s:19:"products_extra_text";s:9018:"<table style="width: 100%; border-collapse: collapse; background: #fff; border-radius: 14px; overflow: hidden; box-shadow: 0 10px 35px rgba(0,0,0,.12); margin: 60px 0; font-size: 15px;">
<tbody>
<tr style="background: #30358C; color: white;"><th style="padding: 20px; text-align: left; font-weight: 600;">Parameter</th><th style="padding: 20px; text-align: left; font-weight: 600;">Value</th></tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">String Inverter Model SUN-12K-G06P3-EU-AM2-P1</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">PV String Input Data</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Max. PV Input Power</td>
<td style="padding: 14px 20px;">18 kW</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Max. PV Input Voltage</td>
<td style="padding: 14px 20px;">1100 V</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Start-up Voltage</td>
<td style="padding: 14px 20px;">140 V</td>
</tr>
<tr>
<td style="padding: 14px 20px;">MPPT Voltage Range</td>
<td style="padding: 14px 20px;">120&#8211;1000 V</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated PV Input Voltage</td>
<td style="padding: 14px 20px;">600 V</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Max. Operating PV Input Current</td>
<td style="padding: 14px 20px;">20 + 20 A</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Max. Input Short Circuit Current</td>
<td style="padding: 14px 20px;">30 + 30 A</td>
</tr>
<tr>
<td style="padding: 14px 20px;">No. of MPP Trackers / Strings per MPP Tracker</td>
<td style="padding: 14px 20px;">2 / 1+1</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">AC Output Side</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated AC Output Active Power</td>
<td style="padding: 14px 20px;">12 kW</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Max. AC Output Apparent Power</td>
<td style="padding: 14px 20px;">13.2 kVA</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated AC Output Current (400 V / 380 V)</td>
<td style="padding: 14px 20px;">17.4 A / 18.2 A</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Max. AC Output Current (400 V / 380 V)</td>
<td style="padding: 14px 20px;">19.2 A / 20 A</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated Output Voltage / Range</td>
<td style="padding: 14px 20px;">220/380 V, 230/400 V (0.85 Un &#8211; 1.1 Un)</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Grid Connection Form</td>
<td style="padding: 14px 20px;">3L/N/PE</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated Grid Frequency / Range</td>
<td style="padding: 14px 20px;">50/60 Hz (45&#8211;55 / 55&#8211;65 Hz)</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Power Factor Adjustment Range</td>
<td style="padding: 14px 20px;">0.8 leading &#8211; 0.8 lagging</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Total Harmonic Distortion (THDi)</td>
<td style="padding: 14px 20px;">&lt; 3 %</td>
</tr>
<tr>
<td style="padding: 14px 20px;">DC Injection Current</td>
<td style="padding: 14px 20px;">&lt; 0.5 % In</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">Efficiency</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Max. Efficiency</td>
<td style="padding: 14px 20px;">98.3 %</td>
</tr>
<tr>
<td style="padding: 14px 20px;">European Efficiency</td>
<td style="padding: 14px 20px;">97.8 %</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">MPPT Efficiency</td>
<td style="padding: 14px 20px;">&gt; 99 %</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">Equipment Protection</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">DC Polarity Reverse Connection Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">AC Output Overcurrent Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">AC Output Overvoltage Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">AC Output Short Circuit Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Thermal Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">DC Terminal Insulation Impedance Monitoring</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">DC Component Monitoring</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Arc Fault Circuit Interrupter (AFCI)</td>
<td style="padding: 14px 20px;">Optional</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Ground Fault Current Monitoring</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Power Network Monitoring</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Island Protection Monitoring</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Earth Fault Detection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Overvoltage Load Drop Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Residual Current (RCD) Detection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Surge Protection Level</td>
<td style="padding: 14px 20px;">Type II (DC), Type II (AC)</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">Interface</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Communication Interface</td>
<td style="padding: 14px 20px;">RS485 / RS232</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Monitoring Mode</td>
<td style="padding: 14px 20px;">GPRS / Wi-Fi / Bluetooth / 4G / LAN (optional)</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">General Data</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Operating Temperature Range</td>
<td style="padding: 14px 20px;">-25 &#176;C to +60 &#176;C (&gt;45 &#176;C derating)</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Permissible Ambient Humidity</td>
<td style="padding: 14px 20px;">0&#8211;100 %</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Permissible Altitude</td>
<td style="padding: 14px 20px;">4000 m</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Noise Emission</td>
<td style="padding: 14px 20px;">&lt; 45 dB</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Ingress Protection Rating</td>
<td style="padding: 14px 20px;">IP65</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Inverter Topology</td>
<td style="padding: 14px 20px;">Non-Isolated</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Over Voltage Category</td>
<td style="padding: 14px 20px;">OVC II (DC), OVC III (AC)</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Cabinet Size (W &#215; H &#215; D)</td>
<td style="padding: 14px 20px;">283 &#215; 463 &#215; 178 mm (excl. connectors and brackets)</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Weight</td>
<td style="padding: 14px 20px;">11 kg</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Type of Cooling</td>
<td style="padding: 14px 20px;">Natural Cooling</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Warranty</td>
<td style="padding: 14px 20px;">5 years</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Grid Regulation</td>
<td style="padding: 14px 20px;">IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G98, G99, VDE-AR-N 4105</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Safety EMC / Standard</td>
<td style="padding: 14px 20px;">IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1/2</td>
</tr>
</tbody>
</table>";s:17:"products_quantity";i:9999;s:16:"manufacturers_id";i:10;s:14:"products_image";s:10:"1033_0.jpg";s:15:"products_weight";s:7:"11.0000";s:26:"products_short_description";s:391:"Deye SUN-12K-G06P3-EU-AM2-P1 12kW Three-Phase String Inverter (EU)<br /><br />Ultra-light and completely silent 12 kW inverter with 98.3 % efficiency, 2 MPPT (120&#8211;1000 V), zero-export &amp; VSG function, optional string monitoring, only 11 kg, natural cooling. IP65, Type II SPD both sides, fully certified (G99, VDE-AR-N 4105 etc.). Ideal for residential and small commercial systems.";s:20:"products_description";s:3907:"<div style="font-family: 'Segoe UI',Arial,sans-serif; max-width: 1000px; margin: 0 auto; line-height: 1.7; color: #333;">
<p style="font-size: 19px; font-weight: 300; color: #222; margin-bottom: 45px;">The Deye SUN-12K-G06P3-EU-AM2-P1 is a state-of-the-art 12 kW three-phase string inverter of the latest generation &#8211; perfectly tailored for residential and smaller commercial solar systems. With a peak efficiency of 98.3 % and a European efficiency of 97.8 %, it delivers outstanding performance. Two independent MPPTs with an extremely wide voltage range of 120&#8211;1000 V and a very low start-up voltage of only 140 V ensure maximum yield even in diffuse light conditions. Zero-export capability, integrated VSG technology for grid support, optional string-level monitoring and optional anti-PID function make this inverter future-proof and highly flexible. Weighing just 11 kg, with compact dimensions of 283 &#215; 463 &#215; 178 mm, natural cooling (completely silent) and IP65 protection, it can be installed by one person &#8211; indoors or outdoors. Comprehensive communication options and full certification to all major European standards complete this top-class package.</p>
<div style="margin: 60px 0;"><img src="https://syd-green-energy.com/files/images/syd-solar-mood-008.jpg" alt="Deye SUN-12K-G06P3-EU-AM2-P1 12kW String Inverter" style="width: 100%; border-radius: 14px; box-shadow: 0 12px 35px rgba(0,0,0,.15);" /></div>
<h3 style="color: #30358c; font-size: 30px; font-weight: bold; margin: 70px 0 40px; text-transform: uppercase; letter-spacing: 1.5px;">Key Advantages</h3>
<div style="display: grid; grid-template-columns: repeat(auto-fit,minmax(380px,1fr)); gap: 28px; margin-bottom: 70px;">
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Excellent Efficiency</strong><br />98.3 % peak &#183; 97.8 % European &#8211; very high yield.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Extremely Low Start-Up</strong><br />Only 140 V start, 120&#8211;1000 V MPPT range.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Zero Export &amp; VSG</strong><br />Perfect for export-limited regions + grid support.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Completely Silent</strong><br />Natural cooling, &lt; 45 dB.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Ultra-Light &amp; Compact</strong><br />Only 11 kg, 283 &#215; 463 &#215; 178 mm, IP65.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Full Protection</strong><br />Type II SPD (DC+AC), optional AFCI &amp; anti-PID.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Smart Monitoring</strong><br />Optional string monitoring, Wi-Fi/4G/LAN.</div>
</div>
<div style="background: #30358C; color: white; padding: 60px 50px; border-radius: 14px; text-align: center; font-size: 26px; font-weight: 600; box-shadow: 0 15px 40px rgba(48,53,140,.5); line-height: 1.5; margin: 70px 0;">
<p>Deye SUN-12K-G06P3-EU-AM2-P1 &#8211; The Silent 12 kW Premium String Inverter</p>
<p style="font-size: 22px; opacity: 0.95; margin-top: 15px;">98.3 % Efficiency &#183; 2 MPPT &#183; Zero Export &#183; VSG &#183; Silent &#183; Only 11 kg &#183; IP65</p>
</div>
</div>";s:11:"products_id";i:1033;s:14:"products_price";s:8:"530.0000";s:25:"products_discount_allowed";d:0;s:12:"products_vpe";i:0;s:19:"products_vpe_status";i:0;s:18:"products_vpe_value";s:6:"0.0000";}i:7;a:21:{s:14:"products_fsk18";i:0;s:23:"products_date_available";s:19:"2025-08-31 00:00:00";s:21:"products_shippingtime";i:1;s:14:"products_model";s:23:"SUN-15K-G06P3-EU-AM2-P1";s:15:"products_master";i:0;s:22:"products_master_status";i:0;s:12:"products_ean";s:0:"";s:13:"products_name";s:62:"SUN-15K-G06P3-EU-AM2-P1 | Three Phase String Inverter | 2 MPPT";s:19:"products_extra_text";s:9026:"<table style="width: 100%; border-collapse: collapse; background: #fff; border-radius: 14px; overflow: hidden; box-shadow: 0 10px 35px rgba(0,0,0,.12); margin: 60px 0; font-size: 15px;">
<tbody>
<tr style="background: #30358C; color: white;"><th style="padding: 20px; text-align: left; font-weight: 600;">Parameter</th><th style="padding: 20px; text-align: left; font-weight: 600;">Value</th></tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">String Inverter Model SUN-15K-G06P3-EU-AM2-P1</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">PV String Input Data</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Max. PV Input Power</td>
<td style="padding: 14px 20px;">22.5 kW</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Max. PV Input Voltage</td>
<td style="padding: 14px 20px;">1100 V</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Start-up Voltage</td>
<td style="padding: 14px 20px;">140 V</td>
</tr>
<tr>
<td style="padding: 14px 20px;">MPPT Voltage Range</td>
<td style="padding: 14px 20px;">120&#8211;1000 V</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated PV Input Voltage</td>
<td style="padding: 14px 20px;">600 V</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Max. Operating PV Input Current</td>
<td style="padding: 14px 20px;">20 + 26 A</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Max. Input Short Circuit Current</td>
<td style="padding: 14px 20px;">30 + 39 A</td>
</tr>
<tr>
<td style="padding: 14px 20px;">No. of MPP Trackers / Strings per MPP Tracker</td>
<td style="padding: 14px 20px;">2 / 1+2</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">AC Output Side</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated AC Output Active Power</td>
<td style="padding: 14px 20px;">15 kW</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Max. AC Output Apparent Power</td>
<td style="padding: 14px 20px;">16.5 kVA</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated AC Output Current (400 V / 380 V)</td>
<td style="padding: 14px 20px;">21.8 A / 22.8 A</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Max. AC Output Current (400 V / 380 V)</td>
<td style="padding: 14px 20px;">24 A / 25 A</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated Output Voltage / Range</td>
<td style="padding: 14px 20px;">220/380 V, 230/400 V (0.85 Un &#8211; 1.1 Un)</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Grid Connection Form</td>
<td style="padding: 14px 20px;">3L/N/PE</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated Grid Frequency / Range</td>
<td style="padding: 14px 20px;">50/60 Hz (45&#8211;55 / 55&#8211;65 Hz)</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Power Factor Adjustment Range</td>
<td style="padding: 14px 20px;">0.8 leading &#8211; 0.8 lagging</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Total Harmonic Distortion (THDi)</td>
<td style="padding: 14px 20px;">&lt; 3 %</td>
</tr>
<tr>
<td style="padding: 14px 20px;">DC Injection Current</td>
<td style="padding: 14px 20px;">&lt; 0.5 % In</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">Efficiency</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Max. Efficiency</td>
<td style="padding: 14px 20px;">98.5 %</td>
</tr>
<tr>
<td style="padding: 14px 20px;">European Efficiency</td>
<td style="padding: 14px 20px;">98.0 %</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">MPPT Efficiency</td>
<td style="padding: 14px 20px;">&gt; 99 %</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">Equipment Protection</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">DC Polarity Reverse Connection Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">AC Output Overcurrent Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">AC Output Overvoltage Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">AC Output Short Circuit Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Thermal Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">DC Terminal Insulation Impedance Monitoring</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">DC Component Monitoring</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Arc Fault Circuit Interrupter (AFCI)</td>
<td style="padding: 14px 20px;">Optional</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Ground Fault Current Monitoring</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Power Network Monitoring</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Island Protection Monitoring</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Earth Fault Detection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Overvoltage Load Drop Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Residual Current (RCD) Detection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Surge Protection Level</td>
<td style="padding: 14px 20px;">Type II (DC), Type II (AC)</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">Interface</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Communication Interface</td>
<td style="padding: 14px 20px;">RS485 / RS232</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Monitoring Mode</td>
<td style="padding: 14px 20px;">GPRS / Wi-Fi / Bluetooth / 4G / LAN (optional)</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">General Data</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Operating Temperature Range</td>
<td style="padding: 14px 20px;">-25 &#176;C to +60 &#176;C (&gt;45 &#176;C derating)</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Permissible Ambient Humidity</td>
<td style="padding: 14px 20px;">0&#8211;100 %</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Permissible Altitude</td>
<td style="padding: 14px 20px;">4000 m</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Noise Emission</td>
<td style="padding: 14px 20px;">&lt; 45 dB</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Ingress Protection Rating</td>
<td style="padding: 14px 20px;">IP65</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Inverter Topology</td>
<td style="padding: 14px 20px;">Non-Isolated</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Over Voltage Category</td>
<td style="padding: 14px 20px;">OVC II (DC), OVC III (AC)</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Cabinet Size (W &#215; H &#215; D)</td>
<td style="padding: 14px 20px;">283 &#215; 463 &#215; 178 mm (excl. connectors and brackets)</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Weight</td>
<td style="padding: 14px 20px;">11 kg</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Type of Cooling</td>
<td style="padding: 14px 20px;">Intelligent air cooling</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Warranty</td>
<td style="padding: 14px 20px;">5 years</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Grid Regulation</td>
<td style="padding: 14px 20px;">IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G98, G99, VDE-AR-N 4105</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Safety EMC / Standard</td>
<td style="padding: 14px 20px;">IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1/2</td>
</tr>
</tbody>
</table>";s:17:"products_quantity";i:9999;s:16:"manufacturers_id";i:10;s:14:"products_image";s:10:"1034_0.jpg";s:15:"products_weight";s:7:"11.0000";s:26:"products_short_description";s:459:"<p dir="auto" style="white-space: pre-wrap;">Deye SUN-15K-G06P3-EU-AM2-P1</p>
<p dir="auto" style="white-space: pre-wrap;">15kW Three-Phase String Inverter (EU) Ultra-compact 15 kW inverter with 98.5 % efficiency, 2 MPPT (120&#8211;1000 V), zero-export &amp; VSG function, optional string monitoring, only 11 kg and &lt;45 dB. IP65, Type II SPD both sides, fully certified (G99, VDE-AR-N 4105, etc.). Perfect for residential and small commercial systems.</p>";s:20:"products_description";s:3895:"<div style="font-family: 'Segoe UI',Arial,sans-serif; max-width: 1000px; margin: 0 auto; line-height: 1.7; color: #333;">
<p style="font-size: 19px; font-weight: 300; color: #222; margin-bottom: 45px;">The Deye SUN-15K-G06P3-EU-AM2-P1 is a highly efficient 15 kW three-phase string inverter of the latest generation, specially developed for residential and smaller commercial solar systems. With a peak efficiency of 98.5 % and a European efficiency of 98 %, it delivers top performance. Two independent MPPTs with an ultra-wide voltage range of 120&#8211;1000 V and a very low start-up voltage of only 140 V guarantee maximum yield even in poor light conditions. Zero-export capability, integrated VSG (Virtual Synchronous Generator) technology for grid stabilisation, optional string-level monitoring and optional anti-PID function make this inverter future-proof and extremely versatile. At just 11 kg and with compact dimensions (283 &#215; 463 &#215; 178 mm) plus IP65 protection, it is perfect for easy wall mounting &#8211; indoors or outdoors. Extensive communication options and full certification to all major European standards round off this outstanding package.</p>
<div style="margin: 60px 0;"><img src="https://syd-green-energy.com/files/images/syd-solar-mood-008.jpg" alt="Deye SUN-15K-G06P3-EU-AM2-P1 15kW String Inverter" style="width: 100%; border-radius: 14px; box-shadow: 0 12px 35px rgba(0,0,0,.15);" /></div>
<h3 style="color: #30358c; font-size: 30px; font-weight: bold; margin: 70px 0 40px; text-transform: uppercase; letter-spacing: 1.5px;">Key Advantages</h3>
<div style="display: grid; grid-template-columns: repeat(auto-fit,minmax(380px,1fr)); gap: 28px; margin-bottom: 70px;">
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Top Efficiency</strong><br />98.5 % peak &#183; 98 % European efficiency &#8211; maximum yield.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Ultra-Low Start-Up</strong><br />Only 140 V start-up, 120&#8211;1000 V MPPT range.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Zero Export &amp; VSG</strong><br />Perfect for export-limited regions + grid support.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Extremely Light</strong><br />Only 11 kg &#8211; single-person installation.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Quiet &amp; Compact</strong><br />&lt; 45 dB, 283 &#215; 463 &#215; 178 mm, IP65.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Full Protection</strong><br />Type II SPD (DC+AC), optional AFCI, anti-PID.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Smart Monitoring</strong><br />Optional string-level monitoring, Wi-Fi/4G/LAN.</div>
</div>
<div style="background: #30358C; color: white; padding: 60px 50px; border-radius: 14px; text-align: center; font-size: 26px; font-weight: 600; box-shadow: 0 15px 40px rgba(48,53,140,.5); line-height: 1.5; margin: 70px 0;">
<p>Deye SUN-15K-G06P3-EU-AM2-P1 &#8211; The Ultra-Compact 15 kW Premium String Inverter</p>
<p style="font-size: 22px; opacity: 0.95; margin-top: 15px;">98.5 % Efficiency &#183; 2 MPPT &#183; Zero Export &#183; VSG &#183; Only 11 kg &#183; IP65</p>
</div>
</div>";s:11:"products_id";i:1034;s:14:"products_price";s:8:"550.0000";s:25:"products_discount_allowed";d:0;s:12:"products_vpe";i:0;s:19:"products_vpe_status";i:0;s:18:"products_vpe_value";s:6:"0.0000";}i:8;a:21:{s:14:"products_fsk18";i:0;s:23:"products_date_available";s:19:"0000-00-00 00:00:00";s:21:"products_shippingtime";i:1;s:14:"products_model";s:11:"SUN-20K-G05";s:15:"products_master";i:0;s:22:"products_master_status";i:0;s:12:"products_ean";s:0:"";s:13:"products_name";s:50:"SUN-20K-G05 | Three Phase String Inverter | 2 MPPT";s:19:"products_extra_text";s:8540:"<table style="width: 100%; border-collapse: collapse; background: #fff; border-radius: 14px; overflow: hidden; box-shadow: 0 10px 35px rgba(0,0,0,.12); margin: 60px 0; font-size: 15px;">
<tbody>
<tr style="background: #30358C; color: white;"><th style="padding: 20px; text-align: left; font-weight: 600;">Parameter</th><th style="padding: 20px; text-align: left; font-weight: 600;">Value</th></tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">String Inverter Model SUN-20K-G05</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">PV String Input Data</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Max. PV Input Power</td>
<td style="padding: 14px 20px;">26 kW</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Max. PV Input Voltage</td>
<td style="padding: 14px 20px;">1100 V</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Start-up Voltage</td>
<td style="padding: 14px 20px;">250 V</td>
</tr>
<tr>
<td style="padding: 14px 20px;">MPPT Voltage Range</td>
<td style="padding: 14px 20px;">200&#8211;1000 V</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated PV Input Voltage</td>
<td style="padding: 14px 20px;">600 V</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Max. Operating PV Input Current</td>
<td style="padding: 14px 20px;">26 + 26 A</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Max. Input Short Circuit Current</td>
<td style="padding: 14px 20px;">39 + 39 A</td>
</tr>
<tr>
<td style="padding: 14px 20px;">No. of MPP Trackers / Strings per MPP Tracker</td>
<td style="padding: 14px 20px;">2 / 2+2</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">AC Output Side</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated AC Output Active Power</td>
<td style="padding: 14px 20px;">20 kW</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Max. AC Output Apparent Power</td>
<td style="padding: 14px 20px;">22 kVA</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated AC Output Current (400V / 380V)</td>
<td style="padding: 14px 20px;">29 A / 30.3 A</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Max. AC Output Current (400V / 380V)</td>
<td style="padding: 14px 20px;">31.9 A / 33.3 A</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated Output Voltage / Range</td>
<td style="padding: 14px 20px;">220/380 V, 230/400 V (0.85 Un &#8211; 1.1 Un)</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Grid Connection Form</td>
<td style="padding: 14px 20px;">3L/N/PE</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated Grid Frequency / Range</td>
<td style="padding: 14px 20px;">50/60 Hz (45&#8211;55 Hz / 55&#8211;65 Hz)</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Power Factor Adjustment Range</td>
<td style="padding: 14px 20px;">0.8 leading &#8211; 0.8 lagging</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Total Harmonic Distortion (THDi)</td>
<td style="padding: 14px 20px;">&lt; 3 %</td>
</tr>
<tr>
<td style="padding: 14px 20px;">DC Injection Current</td>
<td style="padding: 14px 20px;">&lt; 0.5 % In</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">Efficiency</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Max. Efficiency</td>
<td style="padding: 14px 20px;">98.5 %</td>
</tr>
<tr>
<td style="padding: 14px 20px;">European Efficiency</td>
<td style="padding: 14px 20px;">98.0 %</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">MPPT Efficiency</td>
<td style="padding: 14px 20px;">&gt; 99 %</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">Equipment Protection</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">DC Reverse Polarity Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">AC Output Overcurrent Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">AC Output Overvoltage Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">AC Output Short Circuit Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Thermal Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Insulation Impedance Detection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">DC Component Monitoring</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Arc Fault Circuit Interrupter (AFCI)</td>
<td style="padding: 14px 20px;">Optional</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Anti-Islanding Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Residual Current Detection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Surge Protection Level</td>
<td style="padding: 14px 20px;">Type II (DC), Type II (AC)</td>
</tr>
<tr>
<td style="padding: 14px 20px;">DC Switch</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">Interface</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Communication Interface</td>
<td style="padding: 14px 20px;">RS485 / RS232</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Monitoring Mode</td>
<td style="padding: 14px 20px;">GPRS / Wi-Fi / Bluetooth / 4G / LAN (optional)</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">General Data</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Operating Temperature Range</td>
<td style="padding: 14px 20px;">-25 &#176;C to +60 &#176;C (&gt;45 &#176;C derating)</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Permissible Ambient Humidity</td>
<td style="padding: 14px 20px;">0&#8211;100 %</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Permissible Altitude</td>
<td style="padding: 14px 20px;">4000 m</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Noise Emission</td>
<td style="padding: 14px 20px;">&#8804; 50 dB(A)</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Ingress Protection Rating</td>
<td style="padding: 14px 20px;">IP65</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Inverter Topology</td>
<td style="padding: 14px 20px;">Non-Isolated</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Over Voltage Category</td>
<td style="padding: 14px 20px;">OVC II (DC), OVC III (AC)</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Cabinet Size (W &#215; H &#215; D)</td>
<td style="padding: 14px 20px;">362 &#215; 527 &#215; 220 mm (excl. connectors and brackets)</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Weight</td>
<td style="padding: 14px 20px;">20 kg</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Type of Cooling</td>
<td style="padding: 14px 20px;">Intelligent air cooling</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Warranty</td>
<td style="padding: 14px 20px;">5 years</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Grid Regulation</td>
<td style="padding: 14px 20px;">IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Safety EMC / Standard</td>
<td style="padding: 14px 20px;">IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1/2</td>
</tr>
</tbody>
</table>";s:17:"products_quantity";i:9999;s:16:"manufacturers_id";i:10;s:14:"products_image";s:10:"1035_0.jpg";s:15:"products_weight";s:7:"24.0000";s:26:"products_short_description";s:382:"Deye SUN-20K-G05 20kW Three-Phase String Inverter (EU)<br /><br />Ultra-lightweight 20 kW inverter with 98.5 % peak efficiency, dual MPPT (200&#8211;1000 V), and only 20 kg. IP65, extremely quiet (&#8804;50 dB), Type II SPD (DC+AC), optional AFCI, and certified to global standards (VDE-AR-N 4105, G99, EN 50549, etc.). Perfect for commercial rooftops and large residential systems.";s:20:"products_description";s:4086:"<div style="font-family: 'Segoe UI',Arial,sans-serif; max-width: 1000px; margin: 0 auto; line-height: 1.7; color: #333;">
<p style="font-size: 19px; font-weight: 300; color: #222; margin-bottom: 45px;">The Deye SUN-20K-G05 is a state-of-the-art 20 kW three-phase string inverter of the latest generation for commercial and larger residential solar systems. With a peak efficiency of 98.5 % and a European efficiency of 98 %, it belongs to the absolute top class. Two independent MPPTs with an extremely wide voltage range of 200&#8211;1000 V and a start-up voltage of only 250 V guarantee maximum flexibility and highest yield under all light conditions. The comprehensive protection suite, intelligent air cooling (&#8804; 50 dB), Type II surge protection on both DC and AC sides, and optional AFCI ensure maximum safety and longevity. Weighing just 20 kg with compact dimensions (362 &#215; 527 &#215; 220 mm) and IP65 rating, it is perfect for easy outdoor wall mounting. Extensive communication options (RS485/RS232 standard, Wi-Fi/GPRS/4G/LAN optional) and certification to all major international standards (VDE-AR-N 4105, G99, EN 50549 etc.) make the SUN-20K-G05 the ideal choice for modern, future-proof solar projects.</p>
<div style="margin: 60px 0;"><img src="https://syd-green-energy.com/files/images/syd-solar-mood-009.jpg" alt="Deye SUN-20K-G05 20kW String Inverter" style="width: 100%; border-radius: 14px; box-shadow: 0 12px 35px rgba(0,0,0,.15);" /></div>
<h3 style="color: #30358c; font-size: 30px; font-weight: bold; margin: 70px 0 40px; text-transform: uppercase; letter-spacing: 1.5px;">Key Advantages</h3>
<div style="display: grid; grid-template-columns: repeat(auto-fit,minmax(380px,1fr)); gap: 28px; margin-bottom: 70px;">
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Top-Class Efficiency</strong><br />98.5 % peak &#183; 98 % European efficiency &#8211; minimal losses, maximum output.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Dual MPPT &#183; Ultra-Wide Range</strong><br />200&#8211;1000 V, starts at 250 V &#8211; ultimate design flexibility.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Ultra-Light &amp; Compact</strong><br />Only 20 kg, 362 &#215; 527 &#215; 220 mm &#8211; single-person installation.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Quiet &amp; Rugged</strong><br />&#8804; 50 dB, IP65, -25 to +60 &#176;C &#8211; ideal for outdoor use.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Full Protection Suite</strong><br />Type II SPD (DC+AC), optional AFCI, anti-islanding, RCMU, etc.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Complete Connectivity</strong><br />RS485/RS232 standard, Wi-Fi/GPRS/4G/LAN optional.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Global Certification</strong><br />VDE-AR-N 4105, G99, EN 50549, CEI 0-21, IEC 61727 and more.</div>
</div>
<div style="background: #30358C; color: white; padding: 60px 50px; border-radius: 14px; text-align: center; font-size: 26px; font-weight: 600; box-shadow: 0 15px 40px rgba(48,53,140,.5); line-height: 1.5; margin: 70px 0;">
<p>Deye SUN-20K-G05 &#8211; The Ultra-Lightweight 20 kW Professional String Inverter</p>
<p style="font-size: 22px; opacity: 0.95; margin-top: 15px;">98.5 % Efficiency &#183; 2 MPPT &#183; Only 20 kg &#183; IP65 &#183; Global Standards</p>
</div>
</div>";s:11:"products_id";i:1035;s:14:"products_price";s:8:"600.0000";s:25:"products_discount_allowed";d:0;s:12:"products_vpe";i:0;s:19:"products_vpe_status";i:0;s:18:"products_vpe_value";s:6:"0.0000";}i:9;a:21:{s:14:"products_fsk18";i:0;s:23:"products_date_available";s:19:"0000-00-00 00:00:00";s:21:"products_shippingtime";i:1;s:14:"products_model";s:11:"SUN-25K-G05";s:15:"products_master";i:0;s:22:"products_master_status";i:0;s:12:"products_ean";s:0:"";s:13:"products_name";s:50:"SUN-25K-G05 | Three Phase String Inverter | 2 MPPT";s:19:"products_extra_text";s:7149:"<table style="width: 100%; border-collapse: collapse; background: #fff; border-radius: 14px; overflow: hidden; box-shadow: 0 10px 35px rgba(0,0,0,.12); margin: 60px 0; font-size: 15px;">
<tbody>
<tr style="background: #30358C; color: white;"><th style="padding: 20px; text-align: left; font-weight: 600;">Parameter</th><th style="padding: 20px; text-align: left; font-weight: 600;">Value</th></tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">String Inverter Model SUN-25K-G05</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">PV String Input Data</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Max. PV Input Power</td>
<td style="padding: 14px 20px;">32.5 kW</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Max. PV Input Voltage</td>
<td style="padding: 14px 20px;">1100 V</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Start-up Voltage</td>
<td style="padding: 14px 20px;">250 V</td>
</tr>
<tr>
<td style="padding: 14px 20px;">MPPT Voltage Range</td>
<td style="padding: 14px 20px;">200&#8211;1000 V</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated PV Input Voltage</td>
<td style="padding: 14px 20px;">600 V</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Max. Operating PV Input Current</td>
<td style="padding: 14px 20px;">26 + 26 A</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Max. Input Short Circuit Current</td>
<td style="padding: 14px 20px;">39 + 39 A</td>
</tr>
<tr>
<td style="padding: 14px 20px;">No. of MPP Trackers / Strings per Tracker</td>
<td style="padding: 14px 20px;">2 / 2+2</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">AC Output Side</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated AC Output Active Power</td>
<td style="padding: 14px 20px;">25 kW</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Max. AC Output Apparent Power</td>
<td style="padding: 14px 20px;">27.5 kVA</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated AC Output Current</td>
<td style="padding: 14px 20px;">37.9 A / 36.2 A</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Max. AC Output Current</td>
<td style="padding: 14px 20px;">41.7 A / 39.8 A</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated Output Voltage / Range</td>
<td style="padding: 14px 20px;">220/380 V, 230/400 V (0.85 Un &#8211; 1.1 Un)</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Grid Connection Form</td>
<td style="padding: 14px 20px;">3L/N/PE</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated Grid Frequency / Range</td>
<td style="padding: 14px 20px;">50/60 Hz (45&#8211;55 / 55&#8211;65 Hz)</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Power Factor Adjustment Range</td>
<td style="padding: 14px 20px;">0.8 leading &#8211; 0.8 lagging</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Total Harmonic Distortion (THDi)</td>
<td style="padding: 14px 20px;">&lt; 3 %</td>
</tr>
<tr>
<td style="padding: 14px 20px;">DC Injection Current</td>
<td style="padding: 14px 20px;">&lt; 0.5 % In</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">Efficiency</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Max. Efficiency</td>
<td style="padding: 14px 20px;">98.5 %</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Euro Efficiency</td>
<td style="padding: 14px 20px;">98.0 %</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">MPPT Efficiency</td>
<td style="padding: 14px 20px;">&gt; 99 %</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">Equipment Protection</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">DC Reverse Polarity Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">AC Overcurrent / Overvoltage / Short Circuit Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Thermal Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Insulation &amp; Residual Current Monitoring</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Anti-Islanding Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Surge Protection</td>
<td style="padding: 14px 20px;">Type II (DC), Type II (AC)</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">DC Switch</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Arc Fault Circuit Interrupter (AFCI)</td>
<td style="padding: 14px 20px;">Optional</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">Interface &amp; General Data</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Communication Interface</td>
<td style="padding: 14px 20px;">RS485 / RS232</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Monitoring Modes</td>
<td style="padding: 14px 20px;">GPRS / Wi-Fi / Bluetooth / 4G / LAN (optional)</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Operating Temperature Range</td>
<td style="padding: 14px 20px;">-25 &#176;C to +60 &#176;C (&gt;45 &#176;C derating)</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Permissible Ambient Humidity</td>
<td style="padding: 14px 20px;">0&#8211;100 %</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Permissible Altitude</td>
<td style="padding: 14px 20px;">4000 m</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Noise Emission</td>
<td style="padding: 14px 20px;">&#8804; 50 dB(A)</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Ingress Protection Rating</td>
<td style="padding: 14px 20px;">IP65</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Dimensions (W &#215; H &#215; D)</td>
<td style="padding: 14px 20px;">362 &#215; 527 &#215; 220 mm (excl. connectors)</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Weight</td>
<td style="padding: 14px 20px;">20 kg</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Cooling</td>
<td style="padding: 14px 20px;">Intelligent air cooling</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Warranty</td>
<td style="padding: 14px 20px;">5 years</td>
</tr>
</tbody>
</table>";s:17:"products_quantity";i:9999;s:16:"manufacturers_id";i:10;s:14:"products_image";s:10:"1036_0.jpg";s:15:"products_weight";s:7:"24.0000";s:26:"products_short_description";s:382:"Deye SUN-25K-G05 25kW Three-Phase String Inverter (EU)<br /><br />Ultra-lightweight 25 kW inverter with 98.5 % peak efficiency, dual MPPT (200&#8211;1000 V), and only 20 kg. IP65, extremely quiet (&#8804;50 dB), Type II SPD (DC+AC), optional AFCI, and certified to global standards (VDE-AR-N 4105, G99, EN 50549, etc.). Perfect for commercial rooftops and large residential systems.";s:20:"products_description";s:4086:"<div style="font-family: 'Segoe UI',Arial,sans-serif; max-width: 1000px; margin: 0 auto; line-height: 1.7; color: #333;">
<p style="font-size: 19px; font-weight: 300; color: #222; margin-bottom: 45px;">The Deye SUN-25K-G05 is a state-of-the-art 25 kW three-phase string inverter of the latest generation for commercial and larger residential solar systems. With a peak efficiency of 98.5 % and a European efficiency of 98 %, it belongs to the absolute top class. Two independent MPPTs with an extremely wide voltage range of 200&#8211;1000 V and a start-up voltage of only 250 V guarantee maximum flexibility and highest yield under all light conditions. The comprehensive protection suite, intelligent air cooling (&#8804; 50 dB), Type II surge protection on both DC and AC sides, and optional AFCI ensure maximum safety and longevity. Weighing just 20 kg with compact dimensions (362 &#215; 527 &#215; 220 mm) and IP65 rating, it is perfect for easy outdoor wall mounting. Extensive communication options (RS485/RS232 standard, Wi-Fi/GPRS/4G/LAN optional) and certification to all major international standards (VDE-AR-N 4105, G99, EN 50549 etc.) make the SUN-25K-G05 the ideal choice for modern, future-proof solar projects.</p>
<div style="margin: 60px 0;"><img src="https://syd-green-energy.com/files/images/syd-solar-mood-009.jpg" alt="Deye SUN-25K-G05 25kW String Inverter" style="width: 100%; border-radius: 14px; box-shadow: 0 12px 35px rgba(0,0,0,.15);" /></div>
<h3 style="color: #30358c; font-size: 30px; font-weight: bold; margin: 70px 0 40px; text-transform: uppercase; letter-spacing: 1.5px;">Key Advantages</h3>
<div style="display: grid; grid-template-columns: repeat(auto-fit,minmax(380px,1fr)); gap: 28px; margin-bottom: 70px;">
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Top-Class Efficiency</strong><br />98.5 % peak &#183; 98 % European efficiency &#8211; minimal losses, maximum output.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Dual MPPT &#183; Ultra-Wide Range</strong><br />200&#8211;1000 V, starts at 250 V &#8211; ultimate design flexibility.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Ultra-Light &amp; Compact</strong><br />Only 20 kg, 362 &#215; 527 &#215; 220 mm &#8211; single-person installation.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Quiet &amp; Rugged</strong><br />&#8804; 50 dB, IP65, -25 to +60 &#176;C &#8211; ideal for outdoor use.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Full Protection Suite</strong><br />Type II SPD (DC+AC), optional AFCI, anti-islanding, RCMU, etc.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Complete Connectivity</strong><br />RS485/RS232 standard, Wi-Fi/GPRS/4G/LAN optional.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Global Certification</strong><br />VDE-AR-N 4105, G99, EN 50549, CEI 0-21, IEC 61727 and more.</div>
</div>
<div style="background: #30358C; color: white; padding: 60px 50px; border-radius: 14px; text-align: center; font-size: 26px; font-weight: 600; box-shadow: 0 15px 40px rgba(48,53,140,.5); line-height: 1.5; margin: 70px 0;">
<p>Deye SUN-25K-G05 &#8211; The Ultra-Lightweight 25 kW Professional String Inverter</p>
<p style="font-size: 22px; opacity: 0.95; margin-top: 15px;">98.5 % Efficiency &#183; 2 MPPT &#183; Only 20 kg &#183; IP65 &#183; Global Standards</p>
</div>
</div>";s:11:"products_id";i:1036;s:14:"products_price";s:8:"620.0000";s:25:"products_discount_allowed";d:0;s:12:"products_vpe";i:0;s:19:"products_vpe_status";i:0;s:18:"products_vpe_value";s:6:"0.0000";}i:10;a:21:{s:14:"products_fsk18";i:0;s:23:"products_date_available";s:19:"2025-08-31 00:00:00";s:21:"products_shippingtime";i:1;s:14:"products_model";s:11:"SUN-30K-G04";s:15:"products_master";i:0;s:22:"products_master_status";i:0;s:12:"products_ean";s:0:"";s:13:"products_name";s:50:"SUN-30K-G04 | Three Phase String Inverter | 2 MPPT";s:19:"products_extra_text";s:5104:"<table style="width: 100%; border-collapse: collapse; background: #fff; border-radius: 14px; overflow: hidden; box-shadow: 0 10px 35px rgba(0,0,0,.12); margin: 60px 0; font-size: 15px;">
<tbody>
<tr style="background: #30358C; color: white;"><th style="padding: 20px; text-align: left; font-weight: 600;">Parameter</th><th style="padding: 20px; text-align: left; font-weight: 600;">Value</th></tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">String Inverter Model SUN-30K-G04</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">PV String Input Data</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Max. PV Input Power</td>
<td style="padding: 14px 20px;">39 kW</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Max. PV Input Voltage</td>
<td style="padding: 14px 20px;">1100 V</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Start-up Voltage</td>
<td style="padding: 14px 20px;">250 V</td>
</tr>
<tr>
<td style="padding: 14px 20px;">MPPT Voltage Range</td>
<td style="padding: 14px 20px;">200&#8211;1000 V</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated PV Input Voltage</td>
<td style="padding: 14px 20px;">600 V</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Max. Operating PV Input Current</td>
<td style="padding: 14px 20px;">40 + 40 A</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Max. Input Short Circuit Current</td>
<td style="padding: 14px 20px;">60 + 60 A</td>
</tr>
<tr>
<td style="padding: 14px 20px;">No. of MPP Trackers / Strings per Tracker</td>
<td style="padding: 14px 20px;">2 / 3+3</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">AC Output Side</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated AC Output Active Power</td>
<td style="padding: 14px 20px;">30 kW</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Max. AC Output Apparent Power</td>
<td style="padding: 14px 20px;">33 kVA</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated AC Output Current</td>
<td style="padding: 14px 20px;">45.5 A / 43.5 A</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Max. AC Output Current</td>
<td style="padding: 14px 20px;">50 A / 47.9 A</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated Output Voltage / Range</td>
<td style="padding: 14px 20px;">220/380 V, 230/400 V (0.85 Un &#8211; 1.1 Un)</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Grid Connection Form</td>
<td style="padding: 14px 20px;">3L/N/PE</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated Grid Frequency / Range</td>
<td style="padding: 14px 20px;">50/60 Hz (45&#8211;55 / 55&#8211;65 Hz)</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Power Factor Adjustment Range</td>
<td style="padding: 14px 20px;">0.8 leading &#8211; 0.8 lagging</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Total Harmonic Distortion (THDi)</td>
<td style="padding: 14px 20px;">&lt; 3 %</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">Efficiency</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Max. Efficiency</td>
<td style="padding: 14px 20px;">98.6 %</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Euro Efficiency</td>
<td style="padding: 14px 20px;">98.1 %</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">MPPT Efficiency</td>
<td style="padding: 14px 20px;">&gt; 99 %</td>
</tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">General Data</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Operating Temperature Range</td>
<td style="padding: 14px 20px;">-25 &#176;C to +60 &#176;C (&gt;45 &#176;C derating)</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Noise Emission</td>
<td style="padding: 14px 20px;">&#8804; 60 dB</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Ingress Protection Rating</td>
<td style="padding: 14px 20px;">IP65</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Dimensions (W &#215; H &#215; D)</td>
<td style="padding: 14px 20px;">330 &#215; 572 &#215; 206 mm</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Weight</td>
<td style="padding: 14px 20px;">28.7 kg</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Cooling</td>
<td style="padding: 14px 20px;">Intelligent air cooling</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Warranty</td>
<td style="padding: 14px 20px;">5 years</td>
</tr>
</tbody>
</table>";s:17:"products_quantity";i:9999;s:16:"manufacturers_id";i:10;s:14:"products_image";s:10:"1037_0.jpg";s:15:"products_weight";s:7:"26.8000";s:26:"products_short_description";s:403:"Deye SUN-30K-G04 30kW Three-Phase String Inverter (EU)<br /><br />Compact, high-performance 30 kW inverter with 98.6 % peak efficiency, dual MPPT (200&#8211;1000 V), and only 28.7 kg. IP65-rated, intelligent air cooling (&#8804;60 dB), full protection including Type II SPD, and certified to global standards (VDE-AR-N 4105, G99, EN 50549, etc.). Ideal for commercial rooftop and ground-mounted systems.";s:20:"products_description";s:3935:"<div style="font-family: 'Segoe UI',Arial,sans-serif; max-width: 1000px; margin: 0 auto; line-height: 1.7; color: #333;">
<p style="font-size: 19px; font-weight: 300; color: #222; margin-bottom: 45px;">The Deye SUN-30K-G04 is a cutting-edge 30 kW three-phase string inverter designed for commercial and industrial solar systems. Delivering an outstanding 98.6 % maximum efficiency and 98.1 % European efficiency, it ranks among the most efficient inverters in its class. Two independent MPPTs with an ultra-wide 200&#8211;1000 V range and a start-up voltage of just 250 V ensure maximum flexibility and yield in all conditions. A comprehensive protection suite, intelligent air cooling, optional AFCI, and full connectivity make it exceptionally reliable and future-proof. Weighing only 28.7 kg with IP65 rating and operation from -25 &#176;C to +60 &#176;C, it&#8217;s perfect for demanding outdoor installations. Certified to all major global standards (VDE-AR-N 4105, G99, EN 50549, etc.), the SUN-30K-G04 is the ideal choice for high-performance solar projects.</p>
<div style="margin: 60px 0;"><img src="https://syd-green-energy.com/files/images/syd-solar-mood-010.jpg" alt="Deye SUN-30K-G04 30kW String Inverter" style="width: 100%; border-radius: 14px; box-shadow: 0 12px 35px rgba(0,0,0,.15);" /></div>
<h3 style="color: #30358c; font-size: 30px; font-weight: bold; margin: 70px 0 40px; text-transform: uppercase; letter-spacing: 1.5px;">Key Advantages</h3>
<div style="display: grid; grid-template-columns: repeat(auto-fit,minmax(380px,1fr)); gap: 28px; margin-bottom: 70px;">
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Outstanding Efficiency</strong><br />98.6 % peak and 98.1 % European efficiency &#8211; more yield, less loss.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Dual MPPT Wide Range</strong><br />200&#8211;1000 V, starts at 250 V &#8211; ultimate design flexibility.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Full Protection Suite</strong><br />Type II SPD (DC+AC), anti-islanding, RCMU, optional AFCI.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Ultra-Compact &amp; Light</strong><br />Only 28.7 kg and 330&#215;572&#215;206 mm &#8211; easy single-person installation.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Smart &amp; Quiet Cooling</strong><br />Intelligent air cooling, &#8804;60 dB &#8211; long life even in hot climates.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Full Connectivity</strong><br />RS485/RS232 standard, Wi-Fi/GPRS/4G/LAN optional &#8211; perfect remote monitoring.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Global Certification</strong><br />VDE-AR-N 4105, G99, EN 50549, CEI 0-21, IEC 61727 etc.</div>
</div>
<div style="background: #30358C; color: white; padding: 60px 50px; border-radius: 14px; text-align: center; font-size: 26px; font-weight: 600; box-shadow: 0 15px 40px rgba(48,53,140,.5); line-height: 1.5; margin: 70px 0;">
<p>Deye SUN-30K-G04 &#8211; The Compact 30 kW Professional String Inverter</p>
<p style="font-size: 22px; opacity: 0.95; margin-top: 15px;">98.6 % Efficiency &#183; 2 MPPT &#183; IP65 &#183; Only 28.7 kg &#183; Global Standards</p>
</div>
</div>";s:11:"products_id";i:1037;s:14:"products_price";s:8:"980.0000";s:25:"products_discount_allowed";d:0;s:12:"products_vpe";i:0;s:19:"products_vpe_status";i:0;s:18:"products_vpe_value";s:6:"0.0000";}i:11;a:21:{s:14:"products_fsk18";i:0;s:23:"products_date_available";s:19:"0000-00-00 00:00:00";s:21:"products_shippingtime";i:1;s:14:"products_model";s:11:"SUN-40K-G04";s:15:"products_master";i:0;s:22:"products_master_status";i:0;s:12:"products_ean";s:0:"";s:13:"products_name";s:50:"SUN-40K-G04 | Three Phase String Inverter | 3 MPPT";s:19:"products_extra_text";s:8144:"<table style="width: 100%; border-collapse: collapse; background: #fff; border-radius: 14px; overflow: hidden; box-shadow: 0 10px 35px rgba(0,0,0,.12); margin: 60px 0; font-size: 15px;">
<tbody>
<tr style="background: #30358C; color: white;"><th style="padding: 20px; text-align: left; font-weight: 600;">Parameter</th><th style="padding: 20px; text-align: left; font-weight: 600;">Value</th></tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">String Inverter Model SUN-40K-G04</td>
</tr>
<!-- PV String Input Data -->
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">PV String Input Data</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Max. PV Input Power</td>
<td style="padding: 14px 20px;">52 kW</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Max. PV Input Voltage</td>
<td style="padding: 14px 20px;">1100 V</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Start-up Voltage</td>
<td style="padding: 14px 20px;">250 V</td>
</tr>
<tr>
<td style="padding: 14px 20px;">MPPT Voltage Range</td>
<td style="padding: 14px 20px;">200&#8211;1000 V</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated PV Input Voltage</td>
<td style="padding: 14px 20px;">600 V</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Max. Operating PV Input Current</td>
<td style="padding: 14px 20px;">40 + 40 + 40 A</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Max. Input Short Circuit Current</td>
<td style="padding: 14px 20px;">60 + 60 + 60 A</td>
</tr>
<tr>
<td style="padding: 14px 20px;">No. of MPP Trackers / Strings per Tracker</td>
<td style="padding: 14px 20px;">3 / 3+3+3</td>
</tr>
<!-- AC Output Side -->
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">AC Output Side</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated AC Output Active Power</td>
<td style="padding: 14px 20px;">40 kW</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Max. AC Output Apparent Power</td>
<td style="padding: 14px 20px;">44 kVA</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated AC Output Current</td>
<td style="padding: 14px 20px;">60.6 A / 58 A (220 V / 230 V)</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Max. AC Output Current</td>
<td style="padding: 14px 20px;">66.7 A / 63.8 A</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated Output Voltage / Range</td>
<td style="padding: 14px 20px;">220/380 V, 230/400 V (0.85 Un &#8211; 1.1 Un)</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Grid Connection Form</td>
<td style="padding: 14px 20px;">3L/N/PE</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated Grid Frequency / Range</td>
<td style="padding: 14px 20px;">50/60 Hz (45&#8211;55 Hz / 55&#8211;65 Hz)</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Power Factor Adjustment Range</td>
<td style="padding: 14px 20px;">0.8 leading &#8211; 0.8 lagging</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Total Harmonic Distortion (THDi)</td>
<td style="padding: 14px 20px;">&lt; 3 %</td>
</tr>
<tr>
<td style="padding: 14px 20px;">DC Injection Current</td>
<td style="padding: 14px 20px;">&lt; 0.5 % In</td>
</tr>
<!-- Efficiency -->
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">Efficiency</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Max. Efficiency</td>
<td style="padding: 14px 20px;">98.7 %</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Euro Efficiency</td>
<td style="padding: 14px 20px;">98.1 %</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">MPPT Efficiency</td>
<td style="padding: 14px 20px;">&gt; 99 %</td>
</tr>
<!-- Equipment Protection -->
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">Equipment Protection</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">DC Reverse Polarity Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">AC Output Overcurrent / Overvoltage / Short Circuit Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Thermal Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Insulation Impedance / Residual Current Detection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Anti-Islanding Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Surge Protection</td>
<td style="padding: 14px 20px;">Type II (DC), Type II (AC)</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">DC Switch</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Arc Fault Circuit Interrupter (AFCI)</td>
<td style="padding: 14px 20px;">Optional</td>
</tr>
<!-- Interface -->
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">Interface</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Communication Interface</td>
<td style="padding: 14px 20px;">RS485/RS232</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Monitoring Modes</td>
<td style="padding: 14px 20px;">GPRS/Wi-Fi/Bluetooth/4G/LAN (optional)</td>
</tr>
<!-- General Data -->
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">General Data</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Operating Temperature Range</td>
<td style="padding: 14px 20px;">-25 &#176;C to +60 &#176;C (&gt;45 &#176;C derating)</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Permissible Ambient Humidity</td>
<td style="padding: 14px 20px;">0&#8211;100 %</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Permissible Altitude</td>
<td style="padding: 14px 20px;">4000 m</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Noise Emission</td>
<td style="padding: 14px 20px;">&lt; 65 dB</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Ingress Protection Rating</td>
<td style="padding: 14px 20px;">IP65</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Inverter Topology</td>
<td style="padding: 14px 20px;">Non-isolated</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Over Voltage Category</td>
<td style="padding: 14px 20px;">OVC II (DC), OVC III (AC)</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Dimensions (W &#215; H &#215; D)</td>
<td style="padding: 14px 20px;">434 &#215; 570 &#215; 243 mm (excl. connectors)</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Weight</td>
<td style="padding: 14px 20px;">39 kg</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Warranty</td>
<td style="padding: 14px 20px;">5 years</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Cooling</td>
<td style="padding: 14px 20px;">Intelligent air cooling</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Grid Regulation</td>
<td style="padding: 14px 20px;">IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Safety / EMC</td>
<td style="padding: 14px 20px;">IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2</td>
</tr>
</tbody>
</table>";s:17:"products_quantity";i:9999;s:16:"manufacturers_id";i:10;s:14:"products_image";s:10:"1038_0.jpg";s:15:"products_weight";s:7:"46.2500";s:26:"products_short_description";s:482:"Deye SUN-40K-G04 40kW Three-Phase String Inverter (EU)<br /><br />High-performance 40 kW inverter with 98.7 % peak efficiency and three independent MPPTs (200&#8211;1000 V). Supports zero export and VSG, optional string monitoring and anti-PID function. IP65-rated, intelligent air cooling, comprehensive protection features, and certified to global standards (VDE-AR-N 4105, G99, CEI 0-21, EN 50549, etc.). Perfect for medium to large commercial and industrial solar installations.";s:20:"products_description";s:4907:"<div style="font-family: 'Segoe UI',Arial,sans-serif; max-width: 1000px; margin: 0 auto; line-height: 1.7; color: #333;">
<p style="font-size: 19px; font-weight: 300; color: #222; margin-bottom: 45px;">The Deye SUN-40K-G04 is a state-of-the-art 40 kW three-phase string inverter engineered for medium to large commercial and industrial solar projects. Delivering an outstanding 98.7 % maximum efficiency and 98.1 % European efficiency, it sets the benchmark in energy conversion. With support for zero export and VSG applications, a wide 200&#8211;1000 V MPPT range, and optional intelligent string monitoring, it offers unmatched flexibility and precision diagnostics. A comprehensive protection suite, optional anti-PID function, and intelligent air cooling ensure maximum safety and longevity. Featuring IP65 protection, operation from -25 &#176;C to +60 &#176;C, and extensive connectivity (Wi-Fi, GPRS, LAN, etc.), this inverter excels in any environment. Fully compliant with global standards, it guarantees safe, efficient, and future-proof integration worldwide.</p>
<div style="margin: 60px 0;"><img src="https://syd-green-energy.com/files/images/syd-solar-mood-011.jpg" alt="Deye SUN-40K-G04 40kW String Inverter" style="width: 100%; border-radius: 14px; box-shadow: 0 12px 35px rgba(0,0,0,.15);" /></div>
<h3 style="color: #30358c; font-size: 30px; font-weight: bold; margin: 70px 0 40px; text-transform: uppercase; letter-spacing: 1.5px;">Key Advantages</h3>
<div style="display: grid; grid-template-columns: repeat(auto-fit,minmax(380px,1fr)); gap: 28px; margin-bottom: 70px;">
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Top Efficiency</strong><br />98.7 % peak and 98.1 % European efficiency &#8211; minimal losses, maximum performance in all conditions.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Versatile Applications</strong><br />Zero export &amp; VSG capable &#8211; perfectly adapts to diverse grid codes and requirements.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Intelligent String Monitoring</strong><br />Optional per-string monitoring for precise fault detection and optimal maintenance.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Wide MPPT Range</strong><br />200&#8211;1000 V enables flexible system design and maximum yield in varying light conditions.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Full Protection Suite</strong><br />DC reverse polarity, AC overcurrent/overvoltage/short-circuit, anti-islanding, RCMU, etc.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Optional Anti-PID</strong><br />Prevents long-term module degradation &#8211; ensures sustained high performance.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Rugged IP65 Design</strong><br />Dust- and waterproof, -25 &#176;C to +60 &#176;C operation &#8211; built for outdoor use.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Smart Air Cooling</strong><br />Efficient thermal management for reliability even in extreme heat.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Full Connectivity</strong><br />RS485/RS232 standard, Wi-Fi/GPRS/4G/LAN optional &#8211; seamless remote monitoring.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Global Certification</strong><br />VDE-AR-N 4105, G99, CEI 0-21, EN 50549, IEC 61727 etc. &#8211; ready for worldwide deployment.</div>
</div>
<div style="background: #30358C; color: white; padding: 60px 50px; border-radius: 14px; text-align: center; font-size: 26px; font-weight: 600; box-shadow: 0 15px 40px rgba(48,53,140,.5); line-height: 1.5; margin: 70px 0;">
<p>Deye SUN-40K-G04 &#8211; The Professional 40 kW String Inverter for Commercial Solar Systems</p>
<p style="font-size: 22px; opacity: 0.95; margin-top: 15px;">98.7 % Efficiency &#183; 3 MPPT &#183; IP65 &#183; Smart Cooling &#183; Global Standards</p>
</div>
</div>";s:11:"products_id";i:1038;s:14:"products_price";s:9:"1300.0000";s:25:"products_discount_allowed";d:0;s:12:"products_vpe";i:0;s:19:"products_vpe_status";i:0;s:18:"products_vpe_value";s:6:"0.0000";}i:12;a:21:{s:14:"products_fsk18";i:0;s:23:"products_date_available";s:19:"2025-08-31 00:00:00";s:21:"products_shippingtime";i:1;s:14:"products_model";s:11:"SUN-50K-G04";s:15:"products_master";i:0;s:22:"products_master_status";i:0;s:12:"products_ean";s:0:"";s:13:"products_name";s:50:"SUN-50K-G04 | Three Phase String Inverter | 4 MPPT";s:19:"products_extra_text";s:8163:"<table style="width: 100%; border-collapse: collapse; background: #fff; border-radius: 14px; overflow: hidden; box-shadow: 0 10px 35px rgba(0,0,0,.12); margin-bottom: 60px; font-size: 15px;">
<tbody>
<tr style="background: #30358C; color: white;"><th style="padding: 20px; text-align: left; font-weight: 600;">Parameter</th><th style="padding: 20px; text-align: left; font-weight: 600;">Value</th></tr>
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">String Inverter Model SUN-50K-G04</td>
</tr>
<!-- PV String Input Data -->
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">PV String Input Data</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Max. PV Input Power</td>
<td style="padding: 14px 20px;">65 kW</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Max. PV Input Voltage</td>
<td style="padding: 14px 20px;">1100 V</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Start-up Voltage</td>
<td style="padding: 14px 20px;">250 V</td>
</tr>
<tr>
<td style="padding: 14px 20px;">MPPT Voltage Range</td>
<td style="padding: 14px 20px;">200&#8211;1000 V</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated PV Input Voltage</td>
<td style="padding: 14px 20px;">600 V</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Max. Operating PV Input Current</td>
<td style="padding: 14px 20px;">40 + 40 + 40 + 40 A</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Max. Input Short Circuit Current</td>
<td style="padding: 14px 20px;">60 + 60 + 60 + 60 A</td>
</tr>
<tr>
<td style="padding: 14px 20px;">No. of MPP Trackers / Strings per Tracker</td>
<td style="padding: 14px 20px;">4 / 3+3+3+3</td>
</tr>
<!-- AC Output Side -->
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">AC Output Side</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated AC Output Active Power</td>
<td style="padding: 14px 20px;">50 kW</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Max. AC Output Apparent Power</td>
<td style="padding: 14px 20px;">55 kVA</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated AC Output Current</td>
<td style="padding: 14px 20px;">75.8 A / 72.5 A (220 V / 230 V)</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Max. AC Output Current</td>
<td style="padding: 14px 20px;">83.3 A / 79.7 A</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated Output Voltage / Range</td>
<td style="padding: 14px 20px;">220/380 V, 230/400 V (0.85 Un &#8211; 1.1 Un)</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Grid Connection Form</td>
<td style="padding: 14px 20px;">3L/N/PE</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Rated Grid Frequency / Range</td>
<td style="padding: 14px 20px;">50/60 Hz (45&#8211;55 Hz / 55&#8211;65 Hz)</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Power Factor Adjustment Range</td>
<td style="padding: 14px 20px;">0.8 leading &#8211; 0.8 lagging</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Total Harmonic Distortion (THDi)</td>
<td style="padding: 14px 20px;">&lt; 3 %</td>
</tr>
<tr>
<td style="padding: 14px 20px;">DC Injection Current</td>
<td style="padding: 14px 20px;">&lt; 0.5 % In</td>
</tr>
<!-- Efficiency -->
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">Efficiency</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Max. Efficiency</td>
<td style="padding: 14px 20px;">98.7 %</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Euro Efficiency</td>
<td style="padding: 14px 20px;">98.1 %</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">MPPT Efficiency</td>
<td style="padding: 14px 20px;">&gt; 99 %</td>
</tr>
<!-- Equipment Protection -->
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">Equipment Protection</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">DC Reverse Polarity Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">AC Output Overcurrent / Overvoltage / Short Circuit Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Thermal Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Insulation Impedance / Residual Current Detection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Anti-Islanding Protection</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Surge Protection</td>
<td style="padding: 14px 20px;">Type II (DC), Type II (AC)</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">DC Switch</td>
<td style="padding: 14px 20px;">Yes</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Arc Fault Circuit Interrupter (AFCI)</td>
<td style="padding: 14px 20px;">Optional</td>
</tr>
<!-- Interface -->
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">Interface</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Communication Interface</td>
<td style="padding: 14px 20px;">RS485/RS232</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Monitoring Modes</td>
<td style="padding: 14px 20px;">GPRS/Wi-Fi/Bluetooth/4G/LAN (optional)</td>
</tr>
<!-- General Data -->
<tr style="background: #30358C; color: white;">
<td colspan="2" style="padding: 16px 20px; font-size: 17px; font-weight: bold;">General Data</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Operating Temperature Range</td>
<td style="padding: 14px 20px;">-25 &#176;C to +60 &#176;C (&gt;45 &#176;C derating)</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Permissible Ambient Humidity</td>
<td style="padding: 14px 20px;">0&#8211;100 %</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Permissible Altitude</td>
<td style="padding: 14px 20px;">4000 m</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Noise Emission</td>
<td style="padding: 14px 20px;">&lt; 65 dB</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Ingress Protection Rating</td>
<td style="padding: 14px 20px;">IP65</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Inverter Topology</td>
<td style="padding: 14px 20px;">Non-isolated</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Over Voltage Category</td>
<td style="padding: 14px 20px;">OVC II (DC), OVC III (AC)</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Dimensions (W &#215; H &#215; D)</td>
<td style="padding: 14px 20px;">434 &#215; 570 &#215; 243 mm (excl. connectors)</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Weight</td>
<td style="padding: 14px 20px;">39 kg</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Warranty</td>
<td style="padding: 14px 20px;">5 years</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Cooling</td>
<td style="padding: 14px 20px;">Intelligent air cooling</td>
</tr>
<tr>
<td style="padding: 14px 20px;">Grid Regulation</td>
<td style="padding: 14px 20px;">IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105</td>
</tr>
<tr style="background: #f8f9fc;">
<td style="padding: 14px 20px;">Safety / EMC</td>
<td style="padding: 14px 20px;">IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2</td>
</tr>
</tbody>
</table>";s:17:"products_quantity";i:9999;s:16:"manufacturers_id";i:10;s:14:"products_image";s:10:"1039_0.jpg";s:15:"products_weight";s:7:"46.2500";s:26:"products_short_description";s:723:"Deye SUN-50K-G04 50kW Three-Phase String Inverter (EU)<br /><br />The Deye SUN-50K-G04 is a high-performance 50 kW inverter designed for large-scale commercial and industrial solar systems. With a peak efficiency of 98.7 %, a wide 200&#8211;1000 V MPPT range, and support for zero export and VSG applications, it delivers unmatched flexibility and efficiency. Optional intelligent string monitoring, a robust protection suite, and an anti-PID function ensure long-term reliability. Featuring IP65 protection, intelligent air cooling, and extensive communication options (Wi-Fi, GPRS, LAN), it thrives in demanding environments. Certified to IEC 61727, VDE-AR-N 4105, and more, it guarantees global compatibility and safety.";s:20:"products_description";s:5860:"<div style="font-family: 'Segoe UI',Arial,sans-serif; max-width: 1000px; margin: 0 auto; line-height: 1.7; color: #333;">
<p style="font-size: 19px; font-weight: 300; color: #222; margin-bottom: 45px;">The Deye SUN-50K-G04 is a state-of-the-art 50 kW three-phase string inverter engineered for demanding commercial and industrial solar installations. Boasting an exceptional 98.7 % maximum efficiency and a 98.1 % European efficiency, it delivers unparalleled energy conversion performance. Designed for versatility, it supports zero export and Virtual Synchronous Generator (VSG) applications, features a wide MPPT voltage range (200&#8211;1000 V) for flexible system design, and offers optional intelligent string monitoring for precise diagnostics. A comprehensive protection suite, optional anti-PID function, and advanced intelligent air cooling ensure maximum safety and durability. With IP65 protection, a broad operating temperature range (-25 &#176;C to +60 &#176;C), and extensive communication interfaces (Wi-Fi, GPRS, LAN, etc.), this inverter is built to excel in diverse environments. Compliant with major international standards, it guarantees seamless and secure integration into global solar systems &#8211; the ultimate choice for high-performance solar projects.</p>
<div style="margin: 60px 0;"><img src="https://syd-green-energy.com/files/images/syd-solar-mood-011.jpg" alt="Deye SUN-50K-G04 50kW String Inverter" style="width: 100%; border-radius: 14px; box-shadow: 0 12px 35px rgba(0,0,0,.15);" /></div>
<h3 style="color: #30358c; font-size: 30px; font-weight: bold; margin: 70px 0 40px; text-transform: uppercase; letter-spacing: 1.5px;">Key Features</h3>
<div style="display: grid; grid-template-columns: repeat(auto-fit,minmax(380px,1fr)); gap: 28px; margin-bottom: 70px;">
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Unmatched Efficiency</strong><br />Achieves a maximum efficiency of 98.7 % and a European efficiency of 98.1 %, minimizing energy losses and ensuring consistent, high-performance output across various conditions.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Versatile Applications</strong><br />Supports zero export and VSG applications, making it adaptable to diverse grid requirements and regulations &#8211; perfect for flexible commercial installations.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Intelligent String Monitoring</strong><br />Optional intelligent string monitoring provides granular insights into each solar string&#8217;s performance, enabling precise diagnostics and enhanced system maintenance.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Wide Voltage Range</strong><br />Features a 200&#8211;1000 V MPPT voltage range, allowing flexible system design and maximizing energy yield under varying sunlight conditions.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Comprehensive Protection Suite</strong><br />Includes DC reverse polarity protection, AC overcurrent, overvoltage, and short-circuit protection, plus thermal shutdown, anti-islanding, and ground fault monitoring for ultimate safety.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Optional Anti-PID Function</strong><br />The anti-PID function prevents long-term performance degradation in solar panels, ensuring sustained efficiency throughout the system&#8217;s lifespan.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Robust Design</strong><br />IP65-rated for dust and water resistance, with a -25 &#176;C to +60 &#176;C operating range, making it ideal for outdoor installations in challenging environments.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Intelligent Air Cooling</strong><br />Advanced air cooling technology ensures efficient thermal management, enhancing durability and stability even in high-temperature conditions.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Extensive Communication</strong><br />Supports GPRS, Wi-Fi, Bluetooth, 4G, and LAN (optional), plus standard RS485/RS232, for seamless integration and easy system monitoring.</div>
<div style="background: #f8f9fc; padding: 28px; border-radius: 14px; border-left: 7px solid #30358C;"><strong style="color: #30358c; font-size: 19px;">Global Standards Compliance</strong><br />Meets IEC 61727, EN 50549, VDE-AR-N 4105, and other standards, ensuring safe and efficient integration into solar systems worldwide.</div>
</div>
<div style="background: #30358C; color: white; padding: 60px 50px; border-radius: 14px; text-align: center; font-size: 26px; font-weight: 600; box-shadow: 0 15px 40px rgba(48,53,140,.5); line-height: 1.5; margin: 70px 0;">
<p>Deye SUN-50K-G04 &#8211; The High-Performance 50 kW String Inverter for Commercial Solar Projects</p>
<p style="font-size: 22px; opacity: 0.95; margin-top: 15px;">98.7 % Efficiency &#183; Wide MPPT Range &#183; IP65 &#183; Intelligent Cooling &#183; Global Standards</p>
</div>
</div>";s:11:"products_id";i:1039;s:14:"products_price";s:9:"1490.0000";s:25:"products_discount_allowed";d:0;s:12:"products_vpe";i:0;s:19:"products_vpe_status";i:0;s:18:"products_vpe_value";s:6:"0.0000";}}s:1:"e";O:8:"DateTime":3:{s:4:"date";s:26:"2025-12-11 12:53:21.785064";s:13:"timezone_type";i:3;s:8:"timezone";s:13:"Europe/Berlin";}s:1:"g";a:0:{}s:1:"m";N;s:1:"c";N;}